Alemite 3679 Manual de serviço - Página 4

Procurar online ou descarregar pdf Manual de serviço para Instrumentos de medição Alemite 3679. Alemite 3679 12 páginas. Electronic meter

SER 3679
Item No.
1
2
3
Meter Indications
Battery icon appears solid or flashes on
display or LCD values are faded
Meter does not measure accurately
Display blank
Reduced or zero flow
Meter does not count and the flow rate
is normal
Err 1 flashing
Err 2 displays
Revision (5-10)
1
Part No.
393772-9
Kit, Oval Gear
340162
Labels, Fluid
393772-12
Kit, Battery Cap
Figure 2 Electronic Meter Model 3679 - Exploded View

Troubleshooting Chart

Possible Problems
1. Weak batteries
2. Dirty contacts
Incorrect calibration factor
Batteries installed incorrectly
1. Gears jammed
2. Clogged system
1. Gears installed incorrectly
2. Register defective
Damaged register
Temporary lapse in data calculation
4
Description
Solution
1. Replace batteries
2. Clean batteries and terminals
Recalibrate the meter
Install the batteries as indicated on the bottom of
the meter
1. Overhaul metering gear cavity
2. Clean system filter
1. Install the magnet gear (magnets upward) onto
the left post of the body. See Figure 2.
2. Replace meter
Replace meter
Wait until the register updates automatically
Electronic Meter
2
3
Quantity
1
1
2
Alemite, LLC