ELECTRICAL CONNECTIONS

WARNING: THE INSTALLATION OF THIS APPLIANCE SHOULD BE CARRIED
OUT BY A COMPETENT ELECTRICIAN AND BE IN ACCORDANCE WITH THE
CURRENT IEE WIRING REGULATIONS (BS7671-2:2008).
This machine MUST be connected to a 400 Volt, 3 phase 50Hz supply through a
suitably rated isolator switch. It cannot be operated from a single phase
supply.
The user should purchase a suitable connecting cable capable of handling 63
Amps (recommended Cross Sectional Area 10mm
63A (or better) which complies with BSEN 60309. A length of 2-3 metres is
recommended giving mobility to the appliance but without becoming a trip
hazard
If in any doubt, consult a qualified electrician. DO NOT attempt any electrical
work yourself.

SAFETY SYSTEMS

THERMOSTATIC PROTECTION

The Devil 7030 has a manual reset thermal cut out to prevent the unit from
overheating.
If the thermal cut out activates, then turn off the power and disconnect from
the power supply. Allow the heater to cool down for several minutes before
pressing the reset button. Reconnect to the power supply and turn on to
resume operation.
LIST OF CONTENTS
1 x Heater
1 x R/H & 1 x L/H Support Frames
1 x Upper Handle
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
2
) and supply plug rated at
1 x Axle c/w Circlip (2)
2 x Wheel
1 x Fixings Pack