Acorn Controls SV16-LVR Manual de instalação, operação e manutenção - Página 5
Procurar online ou descarregar pdf Manual de instalação, operação e manutenção para Unidade de controlo Acorn Controls SV16-LVR. Acorn Controls SV16-LVR 11 páginas. Temperature/pressure balancing mixing valve
VALVE TRIM INSTALLATION CONTINUES:
9B. SV16-LVR Valve Trim Installation:
Figure 7.
a. Slide valve sleeve 13 over valve body.
b. Place escutcheon with gaskets 6 over
valve sleeve 13 and against finished wall
and secure with screws 8.
c. Push handle 14 onto valve stem and
secure with set screw 15.
BACK-TO-BACK INSTALLATION:
1. For 2" x 6" wall construction, position shower
valve so that center of inlet ports are 2-1/8" ±
1/2" (50mm ± 13mm) from finished wall,
ensuring the outlet port marked "T" is facing
down.
2. For 2" x 4" wall construction position, shower
valve so that center of inlet ports are 1-3/8" ±
1/4" (50mm ± 6mm) from finished wall,
ensuring the outlet port marked "T" is facing
down.
3. Make up connections to the appropriate inlet
ports, marked "H" and "C" on one valve and
reverse on the other, cold supply to "H" and hot
supply to "C". Inlet connections are
combination 1/2" NPT and 1/2" sweat. Refer to
page 6 for cartridge removal and reversal.
4. To continue installations follow steps 4-9A on
page 4 or 9B on page 5.
!
IMPORTANT
To avoid confusion, Hot and Cold inlets need to
be re-identified for future maintenance.
!
IMPORTANT
Excessive overheating of valve during soldering
may damage the cartridge and checkstops. Do
not heat valve any higher than needed to flow
solder. If a higher temperature method is being
used all internal components must be
removed. See figures 8 for cartridge removal
and 10 for temperature limit setting.
Acorn Controls
Division of Acorn Engineering Company
Manual #7802-116-000
SV16 Installation & Operation Manual
6
8
14
15
BACK-TO-BACK DETAIL
VIEW FROM REVERSED SIDE
3
1
" (44)
4
MIN.
1
2
" (64)
2
MAX.
2" X 6" BACK-TO-BACK
INSTALLATION
, A member of Morris Group International
®
13
FINISHED
WALL
FIGURE 7
FINISHED
WALL
3
1
4
MIN.
1
2
2
MAX.
™
Page 5 of 9
Date: 09/01/16
" (44)
" (64)