The PCS-25 and PCS-15 come with an optional stainless steel soak tank ("Soak
Tank") and a UL approved submersible agitation pump. The "on/off" switch for
the Soak Tank is located on the lower left hand corner of the lid.
Prior to turning the agitation tank on:
1) Place the stainless steel tank along the left hand side wall of the working surface,
2) Turn the PCS-25/PCS-15 on by depressing the green "on" switch.
3) As the solvent begins to flow, use the cleaning brush and/or nozzle to fill the
stainless steel soak tank until it covers the pump.
4) Once the soak tank is full you can turn on the pump. The agitation pump will
stay on until it is manually turned off.
Fluid Nozzle – shutoff.
E.
The fluid nozzle flow can be adjusted or turned off by turning the yellow valve handle at
the nozzle's base.
F.
Filter Differential Pressure Gauge.
The PCS-25/WCS-25 model and the PCS-15 use a pressure gauge to indicate when the
filters need replacing. Replace filters when the gauge reads 40 PSI. Operating system
beyond 40 PSI will not damage the unit, however, the quality of the solvent will degrade
beyond 40 PSI.
G.
Fusible Link.
The OSHA Regulated Fusible Link that holds the lid open will release the lid if the
ambient temperature reaches 165 F. Never bend the Fusible Link, as it will weaken it.
WARNING! Do not coat or paint fusible link as this may prevent proper
operation. Inspect fusible link annually and replace if corrosion and/or stress is
evident.
J.
Leveling Bolts.
The front two legs contain bolts, which are used to minimize any rocking from uneven
floors, and will aid in leveling the unit. The unit must be level to work properly.
VII.
CARE AND MAINTENANCE
A.
Sump Maintenance.
From time to time the sump of the Parts Washer needs to be pumped clean. The interval
depends on usage. For motor pools this interval is 3-6 months. For weapons cleaning
this interval is 6 months to 1 year. To dump the sump, first remove the hose on the front
8