2. Unplug the unit from wall receptacle.
3. Remove any soak tanks or supplies located on the working surface.
4. To create access to the filter canister lids for the Cleaner, lift and remove filter access
cover cutout located on left side of work surface. (Older models require a filter wrench
to twist the filter canister lid). Screw off filter canister lid.
4. With the lid off, carefully pull the used filter out of the canister. Rest the used filter
on the working tray to allow it to fully drain.
5. Place a new (Clarus Stock# WP680SR) filter in the canister.
6. Inspect the lid o-ring for wear, replace if needed. Apply a generous amount of
petroleum jelly or grease to the lid o-ring.
7. Replace lid, screwing the lid on hand tight, then one more quarter turn. Do not
overtighten.
8. If lid wrench as used, return it to its proper location. Replace the filter access cover
cutouts.
12