After the completion of acquisition, click [x] in the windows
for real time analysis (preview) and graph to close the
windows.
After the power of the activation laser is adjusted, clicking
[Auto LP] in the [N-STORM] control window automatically
adjusts the laser power so that the number of bright points
is maintained. Also, the upper limit on the power for
automatic adjustment(%) can be specified on the [Max]
box.
2.2.2

Acquiring Images in Continuous Mode

In the example below, the following probe is used.
• Alexa647 dye (Alexa647 activated by Alexa405)
Calibration for 3D-STORM
Before the first 3D-STORM image is acquired, it is necessary to perform calibration. See "2.5 Calibration for
3D-STORM."
1
Click [Settings] in the [N-STORM] control window and
then select [Continuous Mode].
After making this setting, click [OK].
2
Select [3D-STORM] from the list at the top left of the
[N-STORM] control window.
To acquire a 2D-STORM image, select
[2D-STORM].
Chapter 2
STORM Microscopy Operation
16
2