Nikon ARROW ID 3000 Manual de instruções - Página 13
Procurar online ou descarregar pdf Manual de instruções para Instrumentos de medição Nikon ARROW ID 3000. Nikon ARROW ID 3000 36 páginas.
Também para Nikon ARROW ID 3000: Manual de instruções (19 páginas)
■ Changing the measurement display mode
Horizontal Distance mode and Actual Distance mode can be switched.
(Factory default setting is Horizontal Distance mode.)
1. Turn on the power (Confirm the internal display is on).
2. Press and hold the MODE button, then immediately (less than 0.5 secnd) depress the PWR button for less
than 2 seconds.
3. Release your finger from the PWR button to switch the Measrurement display mode.
*If the buttons are not pressed in the correct order, switching will not take place.
Horizontal Distance mode
Horizontal
Distance
Actual Distance mode
N/A
N/A
En
Fr
Actual
Distance
13