System Setup (for reference only – completed during assembly)
Step 1S - Press NEXT and ▼ simultaneously for 5 seconds and release.
Step 2S – Leave as default setting = "SOFTENING".
Press NEXT to go to Step 3S. Press REGEN to exit OEM Softener System Setup.
Step 3S – Leave as default Brining Direction = "dn".
Press NEXT to go to Step 4S. Press REGEN to return to previous step.
Step 4S – Leave as default Fill = "Post".
Press NEXT to go to Step 4S. Press REGEN to return to previous step.
Step 5S – Select the time for the first cycle (Backwash) using ▲ or ▼.
Default = 10 minutes. INCREASE AS NECESSARY BUT DO NOT DECREASE.
Press NEXT to go to Step 6S. Press REGEN to return to previous step.
Step 6S – Select the time for the second cycle (Air Recharge) using ▲ or ▼.
Default = 40 minutes. INCREASE AS NECESSARY BUT DO NOT DECREASE.
The display will flash between cycle number & time, & brine direction (UP or dn).
Press NEXT to go to Step 7S. Press REGEN to return to previous step.
Step 7S – Select the time for the third cycle using ▲ or ▼.
Default = "oFF". DO NOT CHANGE.
Press NEXT to go to Step 8S. Press REGEN to return to previous step.
Step 8S – Select the time for the fourth cycle using ▲ or ▼.
Default = "oFF". DO NOT EXCEED 1 MINUTE.
Press NEXT to go to Step 9S. Press REGEN to return to previous step.
Step 9S – Select the pounds for the fifth cycle using ▲ or ▼.
Default = "oFF". DO NOT CHANGE.
Press NEXT to go to Step 10S. Press REGEN to return to previous step.
Step 10S – Set System Capacity – Leave at Default.
Press NEXT to go to Step 11S. Press REGEN to return to previous step.
Step 11S – Set Volume Capacity – Leave at "oFF"
Regeneration will be triggered by the day override setting, or can be set to regenerate
on specific days of the week.
Press NEXT to go to Step 12S. Press REGEN to return to previous step.
Step 12S – Set Regeneration Trigger using ▲ or ▼.
If Step 11S is set to OFF, Regeneration Trigger can be set to 28 day or 7 day.
Press NEXT to go to Step 13S. Press REGEN to return to previous
Step 13S – Not Shown
Step 14S – Set Relay Operation – "oFF". If set to "oFF", 15S & 16S are not shown.
Press NEXT to go to Step 15S. Press REGEN to return to previous step.