Mounting
Mount
swampfox
Screw Spacing
Model
Horizontal (A)
SF1
153 mm
SF3
217 mm
Mounting Template
Powering
Arrangement
Voltage (nominal, min~max)
24V DC
27.6V DC (24.0~36.0V DC)
12V DC
13.8V DC (12.5~15.0V DC)
12V
LOAD
24V DC
SUPPLY
24V DC Supply & External Load
An external power option can be installed in
13.8V supply up to 1A through pins 2 and 3 of the power connector as shown. This
can be used to power an external device such as a cellular modem.
With the 12V DC powering arrangement, a 12V DC supply is fed into the
connector. This connection is also used to charge an external SLA battery
BATT/DC
when the
swampfox
connector is not used, the
Connect an antenna before powering up swampfox
Installation Guide
against a flat surface using four M5 screws.
Vertical
141 mm
141 mm
A
B
POWER
+
12V SW
-
24VDC
+
is powered via the
swampfox
Outside Dimensions
Width (B)
Height
175 mm
168 mm
240 mm
168 mm
Depth is 125mm, plus front clearance for
wiring (at least 70mm for antenna jack)
Rating Apply Power to
48W
3A
EXT
BATT
/ DC
12V DC Supply or External Battery
swampfox
connection. When the
POWER
's internal battery must be removed.
1
POWER
EXT BATT/DC
-
+
that can provide a switched
Backup Battery
Internal or External
Nil
12V BATT
or SUPPLY
EXT
POWER