ARO Ingersoll-Rand PX10P-FPS Series Manual do operador - Página 3
Procurar online ou descarregar pdf Manual do operador para Bomba de água ARO Ingersoll-Rand PX10P-FPS Series. ARO Ingersoll-Rand PX10P-FPS Series 8 páginas. 1” diaphragm pump
GENERAL DESCRIPTION
The ARO diaphragm pump offers high volume delivery even at low air
pressure and a broad range of material compatibility options available.
Refer to the model and option chart. ARO pumps feature stall resistant
design, modular air motor / fluid sections.
Air operated double diaphragm pumps utilize a pressure differential in
the air chambers to alternately create suction and positive fluid pressure in
the fluid chambers, ball checks insure a positive flow of fluid.
Pump cycling will begin as air pressure is applied and it will continue to
pump and keep up with the demand. It will build and maintain line pres
sure and will stop cycling once maximum line pressure is reached (dis
pensing device closed) and will resume pumping as needed.
AIR AND LUBE REQUIREMENTS
WARNING EXCESSIVE AIR PRESSURE. Can cause pump
damage, personal injury or property damage.
S
A filter capable of filtering out particles larger than 50 microns should
be used on the air supply. There is no lubrication required other than
the O" ring lubricant which is applied during assembly or repair.
S
If lubricated air is present, make sure that it is compatible with the
Nitrile seals in the air motor section of the pump.
INSTALLATION
S
Verify correct model / configuration prior to installation.
S
Retorque all external fasteners per specifications prior to start up.
S
Pumps are tested in water at assembly. Flush pump with compatible
fluid prior to installation.
S
When the diaphragm pump is used in a forced feed (flooded inlet)
situation, it is recommended that a Check Valve" be installed at the
air inlet.
S
Material supply tubing should be at least the same diameter as the
pump inlet manifold connection.
S
Material supply hose must be reinforced, non collapsible type com
patible with the material being pumped.
S
Piping must be adequately supported. Do not use the pump to sup
port the piping.
S
Use flexible connections (such as hose) at the suction and dis
charge. These connections should not be rigid piped and must be
compatible with the material being pumped.
S
Secure the diaphragm pump legs to a suitable surface (level and
flat) to insure against damage by vibration.
S
Pumps that need to be submersed must have both wet and non wet
components compatible with the material being pumped.
S
Submersed pumps must have exhaust pipe above liquid level. Ex
haust hose must be conductive and grounded.
S
Flooded suction inlet pressure must not exceed 10 p.s.i.g. (0.69
bar).
SantopreneR is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P., S LubriplateR is a registered trademark of Lubriplate Division (Fiske Brothers)
PD10P X
VitonR, TeflonR and HytrelR are trademarks of the DuPont Company, S KynarR is a registered trademark of Penwalt Corp.
OPERATING INSTRUCTIONS
S
Always flush the pump with a solvent compatible with the material
being pumped if the material being pumped is subject to setting up"
when not in use for a period of time.
S
Disconnect the air supply from the pump if it is to be inactive for a few
hours.
PARTS AND SERVICE KITS
Refer to the part views and descriptions as provided on page 4 through 7
for parts identification and Service Kit information.
S
Certain ARO Smart Parts" are indicated which should be available
for fast repair and reduction of down time.
S
Service kits are divided to service two separate diaphragm pump
functions: 1. AIR SECTION, 2. FLUID SECTION. The FLUID SEC
TION is divided further to match typical part MATERIAL OPTIONS.
MAINTENANCE
S
Provide a clean work surface to protect sensitive internal moving
parts from contamination from dirt and foreign matter during service
disassembly and reassembly.
S
Keep good records of service activity and include pump in preven
tive maintenance program.
S
Before disassembling, empty captured material in the outlet man
ifold by turning the pump upside down to drain material from the
pump.
FLUID SECTION DISASSEMBLY
1. Remove (60) inlet manifold, (61) outlet manifold.
2. Remove (22) balls, (19 and 33) O" rings and (21) seats.
3. Remove (15) fluid caps.
NOTE: Only Teflon diaphragm models use a primary diaphragm (7) and
a backup diaphragm (8). Refer to the auxiliary view in the Fluid Section
illustration.
4. Remove the (6) diaphragm washer, (7) or (7 / 8) diaphragms, and (5)
backup washer.
NOTE: Do not scratch or mar the surface of (1) diaphragm rod.
FLUID SECTION REASSEMBLY
S
Reassemble in reverse order. Refer to the torque requirements on
page 5.
S
Clean and inspect all parts. Replace worn or damaged parts with
new parts as required.
S
Lubricate (1) diaphragm rod and (144) U" cup with Lubriplate
FML 2 grease (94276 grease packet is included in service kit).
S
For models with Teflon diaphragms: Item (8) Santoprene diaphragm
is installed with the side marked AIR SIDE" towards the pump cen
ter body. Install the Teflon diaphragm (7) with the side marked
FLUID SIDE" towards the (15) fluid cap.
S
Re check torque settings after pump has been re started and run a
while.
R
Page 3 of 8