ARO 7673–A Manual do operador

Procurar online ou descarregar pdf Manual do operador para Perfurar ARO 7673–A. ARO 7673–A 4 páginas. Right-angle drill

OPERATOR'S MANUAL
)
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
''2200" SERIES RIGHT–ANGLE DRILL
IMPORTANT: READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
OPERATING AND SAFETY PRECAUTIONS
Pneumatic tools should always be installed and used in accor-
dance with A.N.S.I. B186.1 ''Safety Code For Portable Air Tools."
CAUTION:
Keep hands and clothing away from rotating end of tool.
Wear suitable eye protection while operating tool.
Use tool only for purposes for which it was intended.
SHUT OFF and DISCONNECT AIR SUPPLY from tool BE-
FORE performing maintenance, service or disassembly of
tool.
WARNING: Repeated prolonged operator exposure to vibrations
which may be generated in the use of certain hand–held tools
may produce Raynaud's phenomenon, commonly referred to as
Whitefinger disease. The phenomenon produces numbness and
burning sensations in the hand and may cause circulation and
nerve damage as well as tissue necrosis. Repetitive users of
hand–held tools who experience vibrations should closely moni-
tor duration of use and their physical condition.
ROUTINE LUBRICATION REQUIREMENTS
Lack of or an excessive amount of lubrication will affect the perfor-
mance and life of this tool. Use only recommended lubricants at
below time intervals:
EVERY 8 HOURS OF TOOL OPERATION – Fill lubricator reser-
voir of recommended F.R.L. with spindle oil (29665). If an in line or
air line lubricator is not used, apply several drops of spindle oil
(29665) in air inlet.
EVERY 40 HOURS OF TOOL OPERATION – Flush tool with a
solution of three parts cleaning solvent and one part light oil. After
flushing, apply a small amount of spindle oil in air inlet and run free
for one minute to insure proper lubrication.
EVERY 160 HOURS OF TOOL OPERATION – Lubricate gear-
ing. Pack bearings, coat shafts and lubricate gears with NLGI #1
''EP" grease (33153). Gearing should contain approximately 1/4
oz. (7 g) of grease. Inject 2 or 3 strokes of grease thru grease fitting
in right–angle housing. Right–angle assembly should contain
approximately 1/8 oz. (3.5 g) of grease.
For parts and service information, contact your local ARO distributor, or the Customer Service Dept. of the Ingersoll–Rand
Distribution Center, White House, TN at PH: (615) 672–0321, FAX: (615) 672–0801.
ARO Tool Products
Ingersoll–Rand Company
1725 U.S. No. 1 North D P.O. Box 8000 D Southern Pines, NC 28388–8000
E2000 INGERSOLL–RAND COMPANY D PRINTED IN U.S.A.
Model 7673–A
AIR SUPPLY REQUIREMENTS
For maximum operating efficiency, the following air supply specifi-
cations should be maintained to this air tool:
AIR PRESSURE – 90 PSIG (6 bar)
AIR FILTRATION – 50 micron
LUBRICATED AIR SUPPLY
HOSE SIZE – 3/8" (10 mm) I.D.
An AROR model C28231–810 air line FILTER/REGULATOR/LU-
BRICATOR (F.R.L.) is recommended to maintain the above air
supply specifications.
RECOMMENDED LUBRICANTS
After disassembly is complete, all parts, except sealed or shielded
bearings, should be washed with solvent. To relubricate parts, or
for routine lubrication, use the following recommended lubricants:
Where Used
Air Motor
''O" Rings & Lip Seals
Gears and Bearings
Released:
Revised:
Form:
ARO Part #
Description
29665
1 qt. Spindle Oil
36460
4 oz. Stringy Lubricant
5 lb. ``EP" - NLGI #1 Grease
33153
1-19-00
1572-2