06
Preparing the ThermaCurve Profile
When cutting the ThermaCurve profile, the following allowances should be made:
Power Connection
/ PCB
Wall length
MINUS
200mm/8''
1. When cutting the ThermaCurve
profile, remove any back capping
to prevent swarf or chips becoming
trapped, which could damage the
heating cable when inserted.
Profile
Internal Corner
Wall length
MINUS
125mm/5''
2. Using a pair of long nose pliers or
similar, 'splay out' the cable channel at
the ends to create a wider, 'bell mouth'
opening. This prevents the heating
cable from snagging.
Profile Length PL
2
Termination
End of Run
1
PCB/ Start
External corner
Wall length
MINUS
25mm/1''
Clockwise System
Special Angle
End Termination
Wall length
MINUS
150mm/6''
Wall
ThermaCurve Profile
3. De burr! Using the rotary de burring
tool (from the spares kit) chamfer the
cut ends. Note; failure to follow 8.2 & 8.3
may invalidate your warranty.
3
Cable Connectors
4
5
Cable Connectors
6
Wall length
MINUS