CAME ZL19N Manual de instalação - Página 3
Procurar online ou descarregar pdf Manual de instalação para Abertura de porta de garagem CAME ZL19N. CAME ZL19N 17 páginas. Control panel for 24v gearmotors

You can also connect:
- gate open warning-lamp;
- the cycle lamp;
- the electro lock;
- the 002LB18 for emergency operations in case of power outages.
Types of defi nable commands:
- opening/closing;
-opening/closing with maintained action;
- partial opening;
- partial stop;
- total stop.
The photocells, after detecting an obstacle, trigger:
- reopening while gate is closing;
- partial stop while gate is opening;
TEC HNI CAL DATA
Maximum allowed power load
power draw when idle
maximum power for 24 V accessories 40 W
circuit insulation class
container material ABS
container protection rating IP54
working temperature -20 / +55°C
4.1 Dimensions, centre distances and anchoring holes
power source 230 V - 50/60 Hz
730 W
200 mA
FU SE TABLE
to protect:
Motor/s
Electronic board (line)
Accessories
Command devices (card)
Electro lock
fuses for:
10 A-F
3.15 A-F
2 A-F
315 mA-F
2 A-F