Reprogramming procedure
PROG
a
SW3
beep
e
f
i
Exiting programming. Briefly press the PROG key g: the PROG LED off. NOTE. If no action is performed, the procedure will automatically end after 30 minutes.
Programming key type. At the "Programming Call Buttons" stage, press the PROG h key for at least 3 seconds and then release it (within 6 seconds), as
soon as the LED PROG lights up and the key back lighting flashes as illustrated in figure i, entering "Programming Button Types/Combinations" as part
of the procedure.
Press the first key of the entry panel in the position indicated until the backlighting LED stops flashing and remains lit.
At the end, exit programming, briefly press the PROG key g: the PROG LED will turn off. If no action is performed, the procedure will end automatically
after 30 minutes.
i
>3''
Entering Programming Mode. Press the PROG a key for at least 3 seconds and then release it (within
6 seconds) as soon as the LED PROG light flashes and the key back lighting lights up as illustrated in
<6''
figure . Failure of the PROG LED to light up, indicates a malfunction. Check the connections and
re-access the programming mode.
PROG
c
SW3
Programming the call keys. Lift the receiver (if present) of the extension that you want to programme
c then press the door lock release
key to be associated with the internal extension e: an acoustic signal will confirm that the setting
was stored. Hang up the receiver again, if necessary f and continue, repeating the same operations
for the other extensions.
g
PROG
SW3
BOUT
<1''
PROG
SW3
<1''
PROG
SW3
M1
M2
Exiting programming. Briefly press the PROG
key i: the PROG LED off. NOTE. If no action is
performed, the procedure will automatically end
after 30 minutes.
and AUX2 buttons. On the entry panel, press the call
h
M1
BOUT
>3''
<6''
PROG
SW3
M2