CAME AGT A200K Manual de instalação - Página 5

Procurar online ou descarregar pdf Manual de instalação para Sistema de intercomunicação CAME AGT A200K. CAME AGT A200K 12 páginas.

CAME AGT A200K Manual de instalação
A/200N
Description
A/200N guarantees the power supply to the HPC/1 entry panel
and a maximum of 20 front plates with 6 buttons HPP/6.
It is provided with the following functions:
- 2 dual-tone call beeps for two entry panels (or for additional
call, e.g. from the landing).
- Power supply and control for solenoid lock (12 V AC, 1 A) via
a relay (inside the device) controlled by a timer, adjustable from
2 to 15 seconds using the potentiometer P1
- Call generator: 2 types of dual-tone beep (up to 3 internal
receivers can be connected in parallel on the same call). The
device can be powered at 12 V DC, for example by a battery or
UPS (terminals +B and 5).
The equipment does not include a battery protection device.
105
105
.
43,5
7,5
57
64,5
Function of terminals and jumpers
Terminal board A
Network
Terminal board B
+B
Input 12 V DC (*)
5
Earth
21
Output 11 V DC
8
Common call output 1
8A
Common call output 2
11
Audio from entry panel
12
Audio to entry panel
23
Output 14 V AC
16
+
NO
Normally open
C
Common
NC
Normally closed
(*) The device is electronically protected against overloads and
short circuits.
Terminal board C
5
Earth
8
Audio to internal receiver
9
Audio to internal receiver
Technical data
Type
50-60 Hz (VAC) power supply
Power consumption (VA)
Output voltages at 11 VDC (mA)
Output voltages at 14 VAC (mA)
Peak output voltages (mA)
Operating output voltages (mA)
Storage temperature (°C)
Operating temperature (°C)
IP Rating
relay contacts
A/200N
230
34
150
650
300
650 (1A)
-25 to +70
0 to +35
IP30