CAME F1000 Manual de instalação - Página 9

Procurar online ou descarregar pdf Manual de instalação para Sistema de abertura de portas CAME F1000. CAME F1000 15 páginas. External automation system with articulated arms for hinged gates
Também para CAME F1000: Instalação standard (16 páginas), Manaul (16 páginas), Instalação standard (12 páginas)

CAME F1000 Manual de instalação
5.7 Adjusting the closing and opening-speed brake microswitches
During opening: release and move the door to the open position desired. Turn the upper cam until the microswitch is activated and screw
the microswitch is activated and screw the screw in the related cam.
During closure (F 1000 only): release the door and move it to the desired closing position. Turn the lower cam until the microswitch is
activated and screw the screw in the related cam.
5.8 Manually releasing the motor
Carry out when motor is not in operation
Release
Lower cam
Handle
Lock
Once finished with mounting, electrical connections and
adjustments, lock the motor back into place and replace the cover
securing it with the 4 issued screws.
ø 3,9x13
In the event of power outages or breakdowns, release the gearmotor
using the apposite handle.
Upper cam
Microswitch