INSTALLATION INSTRUCTIONS / INSTRUCTIONS D'INSTALLATION

POWER AND DATA CONNECTIONS

Power Connection Warnings
Before performing any field wiring, refer to and read the warnings contained in
WARNING! The AFS-700 LED Follow Spot should be connected to a constant circuit or a relay device. It should never be connected
to a dimmer or circuit controlled by a dimmer. Read
fixture.
WARNING! The maximum allowable input current is 20 Amps. Do not overload circuits! Luminaires must be supplied by a branch
circuit protected by a maximum 20 Amp circuit protector. Doit être alimenté par un circuit de dérivation protégé par un maximum de
20 ampères circuit protecteur. Ne surchargez pas les circuits!
WARNING! If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exclusively
available from the manufacturer or his service agent.

Connecting Power

Units are powered via an AC input cable from 100 to 240VAC, 50/60Hz and draw approximately 780 Watts of power. Table 2,
outlines the wire colors and their purpose.
Note: See Figure 5 for wiring connections.
IMPORTANT! The AFS-700 LED Follow Spot must be connected to and properly grounded to an viable earth ground.
6
Power and Data Connections
Table 1: Strobe Operation (via control panel)
Slider Position
0 to 50%
50 to 75%
Strobe Pulse Effect (Slower to Faster)
76 to 100%
"Connecting Power" on page 6
Table 2: AC Input Wiring
Wire Color
Brown or Black
Blue or White
Green/Yellow or Green
Figure 5: PowerCON (Blue AC Input) Connector Wiring
AFS-700 LED Follow Spot
Strobe Operation
Slower to Fast Strobe
Random Strobe Effect
"Important Information" on page
carefully on how to properly connect your
Purpose
Main / (L)ine
(N)eutral
Ground / Earth
Note: The supply cord and connecting
cord should be minimum 14AWG, extra-
hard-usage types such as Type G, S, SE,
SEO, SO, ST, STO, or W.
2.