Alto ENCORE R Manual de resolução de problemas eléctricos - Página 5

Procurar online ou descarregar pdf Manual de resolução de problemas eléctricos para Máquina de chão Alto ENCORE R. Alto ENCORE R 13 páginas.

DRIVE MOTOR REVERSE

Conditions necessary for circuit to work
1. Battery voltage 36VDC
2. Key switch on
3. CB-4&5, FU1 closed
4. 4 - Solenoids 1A & 5 closed
5
5. Seat switch closed
1
1T
12
11
B+
12
1,1A,1B
BATT.
CB-4
10 AMP
IGN.
2
3
ACC
CB-5
10 AMP
3
12
A
T0201/0002
70 AMP
1-4
DRIVE MOTOR REVERSE
A
NEW MODULE
THE SEAT SWITCH JUMPS FROM
THE REV. SOL. TO 1A AND THEN
TO THE FWD. SOL.
25F
25G
25A
SEAT
25W
SW.
25Y
25A
25V
ET-103
W/BRN.
GRN.
ORG.
BLK.
BLK./WHT
WHT
25
19
1A
1A
M
M
FU-1
36 V BATTERY BANK
25Y
25
11
11
25V
9B
7K
9A
1207-1141
16 PIN
M-
B-
A2
B+
C
C
C
A1
T201
B
16
11
11A
REV. MTR. SOL.
25Y
5
25
REV.
25W
9A
9
16
9
8
1
17
38
19
39
A1
A1
2+ HP
ARM
DRIVE MTR.
A2
5A
FIELD
S1
C
American-Lincoln Technology
ENCORE R Troubleshooting Guide
7,7C,7H,
77,77C,77D
17
7K
S2
5B
D