Calculation of Magnetite from MF500M+ readings
Placing the probe on any point on the surface of the pipe
slowly move the probe around the surface of the pipe keeping
the face of the probe at a tangent to the pipe surface. noting
the points where the reading is the highest and lowest S
max
and S
.
min
Now you need to decide whether the magnetite is coating the
whole of the inside surface of the pipe or just a sector (as
would happen with a horizontal pipe where either flakes of
magnetite have accrued or the water has not fully filled the
pipe). From the analysis we have done, if the ratio S
/S
<
max
min
1.5 then the accrual might be deemed to be evenly coated.
Starting at the point where the signal is a maximum (S
)
max
with a chalk mark to indicate this position, slowly move the
probe round the pipe maintaining the probe at a tangent to the
pipe surface until the signal has fallen to S
/2. Mark the pipe
max
again. Repeat the procedure in the other direction. In each
case note the angle from the S
position take the average of
max
these as θ (the half angle).