Trouble/Problem
C
burner soots
D
burner disconnects during
operation
E
regulation safety block
switches over (at opened
trigger gun on/off)
F
pressure too low
Cause
f)
oil nozzle clogged
g)
oil pump defective
*h) controller turned off
*i)
dirty probe
j)
not enough water
k)
thermal cutout blown
a)
oil pressure too high,
consequently not enough air
supply, dirty blower wheel
b)
for possible causes,
refer B b)e)f)g)h)
c)
motor speed too low
a)
water-tap shut
b)
not enough water qantity
available
c)
float valve clogged
d)
suction and pressure valve of
high pressure pumpe
defective or dirty
e)
filter clogged
*f) cleaning and care agents bin
empty
g)
filter of hp pump clogged
a)
high pressure nozzle dirty
b)
machine calcified
c)
wrong hp nozzle installed
d)
regulation safety block
misadjusted
a)
cleaning and care agents
container* empty
b)
high pressure nozzle worn out renew it (refer 2.4)
c)
air in the system
Elimination
clean nozzle and strainer, replace
if necessary - for cause, refer B b)
exchange it, for causes, refer Ba) - b)
for possible causes, refer B a) - h),
press supression button
clean it
for cause, refer D a) - g)
check for cause, eliminate cause, put
in new thermal cutout
cut oil pressure, have combustion
adjusted by your works mechanic,
clean heating coil if it is heavily
sootetd
refer operatin instructions Honda
open it
re-check water pressure (refer 4.2)
clean valve and filter
dismount valves, clean and/or replace
these. Clean suction hose filter,
de-aerate the pumpe
clean it
re-fill it, de-aerate pump
clean it
unscrew and clean it
decalcify as per the respective
instructions (refer chapter 5.
maintanance)
apply hp nozzle as per 2.4
have it re-adjusted by the works
mechanic
fill it up
refill cleaning an care agents
container*, retighten all screwing at
hp pump and additives lines (refer D
a) - f)), after trouble elimination,
unscrew hp hose from machine and
have pump run in depressureized
condition
29