diversey QFM Manual de instalação e configuração - Página 8

Procurar online ou descarregar pdf Manual de instalação e configuração para Dispensador diversey QFM. diversey QFM 11 páginas.

diversey QFM Manual de instalação e configuração
QFM
CAUTION: When attaching the pick-up tube, a longer tube may be required than
supplied. If a longer tube is required ensure that the inside diameter is no smaller
than 6mm and should ideally be 10mm, especially if the product is viscous. A
6/10mm adapter is available from JDE for this purpose.
NOTE: It is extremely unlikely that you will have to disconnect the chemical
lines, as the unit can be serviced with the lines connected.
Place the ceramic weight over the end of the chemical pick-up tube and then insert the footvalve. It is important
to add the footvalve, because without it the tube will lose prime when the system is not in use. This will result in
weaker solutions than those specified in the next table.
Turn on the water supply to the unit.
Insert the A-D metering peg in as shown, with the "A" facing down (Fig 1.9). Hold down the wishbone long
enough to fill the pickup tube with chemical.
Figure 1.9 Inserting Metering Peg, "A" Facing Down
Page 8 of 11
Installation & Setup Guide
6mm ID 30m coil
10mm ID 30m coil
Adapter 20pk
(See Spare parts guide for
part numbers).
DE1548 INT issB s1 July 2012