Q3 – Operation Manual

Detail

Detail will increase or decrease the picture sharpness but will also affect the noise in the
picture.

Chroma

Chroma affects the amount of colour saturation in the picture. This can be used to good
effect when matching Q3 to other makes of camera.
IR
IR stands for 'Infra-Red' and switches the camera to monochrome and greatly increases the
sensitivity in low light levels. An Infra-Red lamp may also be used to illuminate the viewing
area. Note that when using purely infra-red light to illuminate a scene the focus may not be
correct. An option in the OSD screen can be set to correct the focus in this case. Select
OSD>Mode>AutoICR>FocusAdj ON/OFF to change this setting. Note this should only be
changed when the lighting is entirely from an Infra-Red lamp. There is also an 'Auto IR'
setting which will enable the camera to automatically switch to IR when the light level drops
to a point where the 'auto gain' has increased beyond 36db. The 'Auto IR' option is only
available in 'Auto Iris' mode.

AWC Mode

AWC mode sets how the colour of the camera is controlled. The default is 'Manual' which
gives control to the red and blue colour knobs on the RCP. Other settings include 'ATW'
which automatically adjusts the camera colour depending on the picture content. Also, fixed
colour settings for 5600k and 3200k lighting types.

Gamma

Gamma controls the picture brightness in dark areas of the image. A lower gamma setting
increases the brightness in dark areas and a high gamma value reduces the brightness in
dark areas. The picture noise is increased for low gamma settings.

Noise Red (Noise Reduction)

There are three settings here On, Off and Auto. The effect is to decrease the picture noise
using a 'Median Filter' at the expense of a slight reduction in resolution. The 'Auto' setting
will automatically insert the noise filter as the gain level is increased.

Iris Area

The Iris area setting is used by the 'Auto Iris' function to determine which area of the picture
is used to set the auto iris level. As the up/down function buttons are pressed, a brief
display of a rectangle on the screen will show the area selected for the auto iris adjustment.

Iris Speed

Iris speed sets the speed at which the iris responds when in auto mode. This will probably
need to be 'Slow' when there is a lot of light and the iris is nearly closed to prevent 'hunting'.
th
Q3
Operation Manual V3.1
Page 9
4
April 2014