ISO 5752 Flanged Body style
For ISO body style valves, the flange free holes
shall be assembled with studs whose lengths are as
specified in the standard ASME B 16.5 and threaded
holes shall be assembled with the bolts and studs whose
lengths are as recommended in table 3.
Recommended bolt and stud lengths for installation in ASME B16.5 flanges are provided in the Table 3
Valve
Size
Class
150
3''
300
150
4''
300
600
150
6''
300
600
150
300
8''
600
150
10''
300
600
150
12''
300
600
150
14"
300
600
Installation, Operation and Maintenance Manual
Table 3
Bolt Circle
Bolt Size
Dia. (in.)
6
5/8-11 UNC
6.63
3/4-10 UNC
7.5
5/8-11 UNC
7.88
3/4-10 UNC
8.5
7/8-9 UNC
9.5
3/4-10 UNC
10.63
3/4-10 UNC
11.5
1-8 UNC
11.75
3/4-10 UNC
13
7/8-9 UN
1 1/8-8
13.75
UNC
14.25
7/8-9 UNC
15.25
1-8 UNC
17
1 1/4-8 UN
17
7/8-9 UNC
17.75
1 1/8-8 UN
19.25
1 1/4-8 UN
18.75
1-8 UNC
20.25
1 1/8-8 UN
20.75
1 3/8-8 UN
ISO Body
Stud length "A"
Qty.
(in.)
_
_
8
3.09
8
2.80
8
3.13
8
4.28
8
2.97
8
3.40
8
5.18
8
3.17
8
3.83
8
5.70
8
3.44
8
4.41
8
6.44
8
3.50
8
4.86
8
6.44
8
4.22
8
5.18
16
6.97
11
TOV
Threaded hole
Quantity
specified in
Table 3.
Cap screw
length "B" (in.)
_
2.21
2.05
2.26
3.28
2.09
2.53
4.05
2.29
2.83
4.44
2.43
3.28
5.07
2.50
3.60
5.07
3.09
3.92
5.48