3DS MAX1024 Manual do utilizador - Página 8
Procurar online ou descarregar pdf Manual do utilizador para Controlador 3DS MAX1024. 3DS MAX1024 11 páginas. Solar controller
Solar charge controller MAX series User Manual
5.3.6 Optically controlled spot
5.3.7 Optical delay
5.3.8 Short circuit protection
5.3.9 PWM charging Settings (Lithium batteries)
If the load mode is selected "USE", then you can switch on and off the load
output manually by pressing MENU shortly.
1.If the controller turns off the load due to low voltage protection、
overcurrent protection、short-circuit protection or over temperature
protection, the load will turn onautomatically when the controller recovers
from protection state.
2.Please note: Pushing the MENU button can still activate the function of
the key, even during of the above four kinds protection states.
The controller automatically identifies day and night by measuring the open circuit
voitage of the solar panel. Depending on the location and the different solar panels,
the user can set different day/night threhold voltage).
Liquid, GEL, AGM:The voltage setting
Lithium:The voltage setting
When the night comes, the controller identifies the day/night threhold voltage.
Through modifying the "day/ night threhold delay" to put off the lighting time.
Setting range is 0~60 seconds (step length is 5 seconds) and 1~30 minutes (step
length is 1 minute) (the default setting is 0 seconds).
When the inductive or capacitive load is started, there will be a large current, which
may
trigger the short-circuit protection of the controller and cause the output
turn off. In this
case, the user can turn off the short-circuit protection function.
is enabled, SoF is disabled, and the default state is enabled.
Seting info:keep the defaults
PWM has the potential to cause noise and interference in the system, especially
when using lithium batteries with BMS, PWM charging may trigger BMS protection
,resulting in system failure. Therefore, the customer can choose to turn off the
PWM, in this mode once the batteryvoltage is charged to the preset voltage, the
controller immediately stops charging, until the battery voltage drops, and then
restart the charging.PoN is enabled,PoF is disabled,and the default value is enabled.
Seting info:keep the defaults
Page 7 of 10 pages
range:
3.0~10.0V/6.0~20.0V(default:8.0/16.0V).
range:
3.0~20.0V(default:8.0V).
.
.
to
SoN