IOM FOR DYNATORQUE™ SANDWICH DECLUTCHING MANUAL OVERRIDE (SD TYPE)
B. Maintenance: DYNATORQUE manual operators do not require periodic maintenance. They are,
for most applications, lubricated for life, with all components designed to have a life equal to or
exceeding the wear life of the operator gearing.
C. Lubrication: If for any reason, lubrication replacement is necessary, Cameron recommends
replacement of that lubrication with:
DYNATORQUE Standard Grease Specification:- Alpha Green 2000
NLGI Grade: Grade 2 EP
Grease Base: Calcium Sulfonate
Color: Green
Anti-Wear EP Additives: Yes
Dropping Point: ASM D566 572Deg F(300Deg C)
4 Ball Wear KG Load ASTM 2596: 500
Timken OK Load Lbs. ASTM 2509: 65
Oil Separation, ASTM D1742-24Hous@77 deg F (25 Deg C)
Base Oil Viscosity SUS @100 Deg F 600
Base Oil Viscosity SUS @210 Deg F 70
Pour Point +5 Deg F
D. Spare Parts: Cameron warrants work performed by the factory or by factory trained personnel
only. Please consult the factory or your local DYNATORQUE representative to arrange
assistance. Cameron modifies a great percentage of its DYNATORQUE operators to meet
specific customer requirements. Please refer to the operator part list number as supplied on the
shipping document, acknowledgement, or invoice, when ordering spare parts.
E. Spare Parts: For your records, please enter the operator part number from your shipping
documents, acknowledgement, or invoice here:
Part Number:
_________________________
Date Stamp:
_________________________(Located on the bottom of the operator housing.)
Purchase / Sales Order Number:
Please Note:
When assembling Cameron DYNATORQUE products to a valve or to an automated valve package, standard
engineering practices must be utilized to assure proper mounting orientation, configuration, and distribution of
weights and forces. Failure to do so could cause product damage and/or malfunction, and void warranty
consideration. If there are any questions please contact the factory at [email protected].