11
Integration in IP-Symcon / ESERA-Station
Via our website we provide ESERA IP-Symcon software modules for reading the
1-Wire Outdoor - Multisensor in IP-Symcon via 1-Wire Controller/1-Wire Gateway. Thus no scripts are
necessary. Details can be found on the ESERA website under "Compatible controllers/central units/IP-
Symcom-Integration"
https://www.esera.de/kompatible-steuerungen-zentralen/ip-symcon-integration/
For the conventional connection via 1-Wire Bus coupler the sensor values have to be calculated according to
the given formulas.
12
Integration in Loxone
Via the shop we provide an example project among others for the reading of the 1-Wire Outdoor -
Multisensor per 1-Wire Controller/1-Wire Gateway. For details see here:
https://www.esera.de/kompatible-steuerungen-zentralen/loxone-integration/demo-1-wire-controller-1-loxone-
integration/
13
Integration in FHEM
For integration into the open source automation software FHEM, we provide a software module for reading in
the 1-Wire Outdoor - Multisensor via 1-Wire Controller/1-Wire Gateway. This means that evaluation scripts
are no longer necessary.
Details can be found on the ESERA website under "Compatible controllers - control units / FHEM
integration".
https://www.esera.de/kompatible-steuerungen-zentralen/fhem-integration/
14
Commissioning and Warm-up
The Air Quality Sensor integrated in the 1-Wire Outdoor - Multisensor does not require any warm-up time.
15
Calibration and Adjustment
The EOS 100 is pre-calibrated. Calibration is not necessary and possible.
16
Measurement accuracy
The sensor elements within the EOS 100 are pre-calibrated. Please note that the measuring accuracy may
possibly be reduced to the measuring range limits and at very high and low operating temperatures.
17
Terminal assignment
The EOS 100 is connected via push-in terminals.
The connection terminal is designed for solid or fine-stranded 0.2 to 1.5 sq. mm cross-section.
The terminal assignment is printed on the printed circuit board. The correct polarity must be observed when
connecting. The EOS 100 must be connected with three cables (ground, 1-wire data and 5V) and should be
connected to functional ground (FE). The parasitic mode is not supported
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH 2021
www.esera.de
11169 V1.0 R1.1 Manual