6. Electrical connections
The signal isolator SIRAX TI 807 is plugged onto a backplane
BP 902. A 96 pin connector (Model C, DIN 41 612) estab-
lishes the electrical connections between the transmitter
and the backplane. The pin connections can be seen from
Fig. 5 and 6.
Please refer to our backplane instructions for the back-
plane wiring.
Make sure that the cables are not live when
making the connections!
In the case of "Intrinsically safe" explosion-
proof versions [EEx ib ] IIC or [EEx ia] IIC,
the supplementary information given on the
type test certificate and also local regula-
tions applicable to electrical installations
in explosion hazard areas must be taken
into account.
Note that, ...
... the required electrical insulation and trans-
mission data agree with the data on the
nameplate of the SIRAX TI 807 (
signals and
... in the case of a signal isolator with current
outputs 0...20 mA, the total resistance of
the external leads (receiver plus leads)
does not exceed the maximum burden of
1000 Ω (non-Ex version) or 500 Ω (Ex
version)! See "Output signal" in Section "4.
Technical data"!
... in the case of a signal isolator with voltage
output 0...10 V , the external receiver con-
nected across the output has a sufficiently
high internal resistance Ri
SIRAX TI 807 output impedance of 500 Ω!
See "Output signal" in Section "4. Technical
data"!
The error due to Ri
500 [Ω] · 100
F [%] =
... the input and output cables should be twisted
pairs and run as far as possible away from
heavy current cables!
14
input
output signals)!
in relation to the
A
is:
A
Ri
[Ω]
A
Signal isolator with two or three isolation and
transmission channels
Back
c
b
a
–
1
+
2
A
–
3
4
+
5
B
6
–
+
7
8
C
D
E
14
F
G
20
H
I
+
K
–
26
27
+
L
28
–
29
+
30
M
31
–
32
Back
b
a
c
–
1
+
2
A
–
3
4
+
5
B
6
–
+
7
8
C
D
E
14
F
G
20
H
I
+
K
–
26
27
+
L
28
–
29
+
30
M
31
–
32
E1, E2, E3
= Input signals
A1, A2, A3 = Output signals
A1
A2
A3
Fig. 5.
Type 807-61..,
Standard (non-Ex)
version
E1
and
E2
Type 807-66..,
Ex version,
E3
(output signals
intrinsically safe)
E1
E2
E3
A1
Fig. 6.
A2
Type 807-62..,
Ex version,
A3
(input signals
intrinsically safe)