esera automation 19200 Manual do utilizador - Página 3

Procurar online ou descarregar pdf Manual do utilizador para Equipamento de gravação esera automation 19200. esera automation 19200 10 páginas. W/auto-e-connect

esera automation 19200 Manual do utilizador
Art. No. 19200
The Auto-E-Connect function automatically recognizes ESERA chips, sensors and actuators, starts suitable
libraries and outputs fully formatted data.
The Auto-E-Connect functionality will be available from mid-2020 via 1-Wire Controllers, 1-Wire Gateways and
1-Wire ECO from ESERA available.
Further information on ESERA Auto-E-Connect can be found on the ESERA website, ESERA Config-Tool 3, or in
the download area for this article in the ESERA Webshop.
4
Technical data
Embedded Computer
CPU:
Memory:
Operating system:
Software, option:
External interface:
System clock (RTC):
1-Wire Gateway
Data interface:
Internal interface:
Firmware update and
configuration
1-Wire interface:
Protection circuits:
Connection:
Output voltage:
Digital- /binary input:
Digital- /binary output:
System clock (RTC):
Entire system
Power supply:
Input:
5

Ambient conditions

Temperature, operation -10 °C up to +55 °C (extended temperature range available upon request)
Air humidity:
Protection system:
Protection class:
Dimensions:
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de
Quad-Core processor ARM-Cortex-A53 64Bit, 1400 MHz
RAM 1024 MB LPDDR2 memory
microSD card 8GB for operating system and software application
Linux Debian (Raspian), software already installed
- IP-Symcon, basic, professional or unlimited
- Codesys 3.x
LAN RJ45 10/100/1000 Mbit (Gigabit LAN by USB 2.0 with up to 300 Mbit)
- Auto negotiation (full-duplex and half-duplex)
- Support for DHCP and IP-address
- DNS support
- Auto MDI/MDIX
WLAN 802.11 b/g/n/ac (2,4 + 5,0 GHz)
Bluetooth 4.2
DS1307 with ability to bypass power failure with Goldcap for min. 24 hours
Modbus RTU and ESERA ASCII text protocol
serial, 19200 baud 8 data bit, 1 start bit, no stop bit
by ESERA Config-Tool 3
1-Wire bus (Masse/GND, 5V, 12V and data)
ESD- and reverse polarity protection
Push In connector for cables up to 1.5qmm cable cross section
5V max. 1A, 12VDC max. 1,2A
Overload and short circuit proof
2 x input 10-30VDC, max. 10mA per channel
isolated with common negative pole
Push In connector for cables up to 1.5qmm cable cross section
2 x output (relays) 16A switching current (NO), isolated
Push In connector for cables up to 2.5qmm cable cross section
DS1307 with ability to bypass power failure with Goldcap for min. 24 hours
16 – 30 VDC
3,4 – 38W*
* depending on the CPU load and load on the 1-wire interface
10 – 92 % (non-condensing)
IP20
III
35 x 90 x 70mm (WxHxD)
19200 V2.0 R1.0 Manual
Page 3 of 10