esera automation 19200 Manual do utilizador - Página 8

Procurar online ou descarregar pdf Manual do utilizador para Equipamento de gravação esera automation 19200. esera automation 19200 10 páginas. W/auto-e-connect

esera automation 19200 Manual do utilizador
15
Internal communication among 1-Wire Gateway and Embedded Computer
15.1
ESERA ASCII text protocol / programming manual
The 1-Wire Gateway inside the ESERA-Station 200 provides two types of protocols. The ESERA text protocol in
ASCII format easily supports configuration and analysis whereas the ESERA text protocol runs on "GET" and
"SET" commands.
The ESERA text protocol is totally open and documented. The latest version of the ESERA protocol description is
available for download in our webshop
controller-1-wire-gateway/) as well as in the ESERA Config-Tool 3 download area.
15.2

Modbus protocol

ESERA-Station 200 is able to communicate to ESERA text protocol or Modbus TCP protocol with no switching.
For communication any Modbus slave-address (device address) can be chosen. Device address equals the
1-wire Gateway / Controller number. Device address is set to 1 by default.
The Modbus protocol is standardized configured. Please refer to the following table for a partial address-
overview. The entire addressing overview can be found in the programming manual, which can be found in the
download area of this product on our website and by the configuration software ESERA "Config Tool 3".
Partial Modbus address specification
Specification
Controller No.
Article-No.
Firmware Version
Hardware
Serial number
Time
Date
...
1-Wire bus sensors and
actuators
OWD 1/1-Wire module 1
OWD 2/1-Wire module 2
16

Operating conditions

The operation of the assembly group can take place only on condition of observing the required voltage and the
ambient conditions. The operating position of the device is irrelevant. The device is meant to be used in dry areas
free of dust.
Should condensed water build up within the sensor, an acclimatization period of at least 2 hours must be met. The
components can be operated only under the supervision of an electrically skilled person. Assembly groups and
components do not belong into the hands of children
In industrial facilities, the accident prevention regulations of the federation of industrial professional associations for
electrical installations and equipment must be observed. Do not operate the components in an environment with
inflammable gases, vapors or dusts or in an environment where such gases, vapors or dusts may occur.
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de
(https://www.esera.de/produkte/software/downloads-firmware-1-wire-
reading address
60000
60001
61000
61010
61020
61030
61035
40100
40101, 40102
40103, 40104
40105, 40106
40107, 40108
40109, 40110
40111, 40112
40113, 40114
40115, 40116
40200
40201, 40202
40203, 40204
...
19200 V2.0 R1.0 Manual
number of words
(16Bit)
1
1
4
3
9
4
4
1
2
2
2
2
2
2
2
2
1
2
2
type of data
text
text
string
string
string
string
string
Integer
Dword1
Dword2
Dword3
Dword4
Dword5
Dword6
Dword7
Dword8
Integer
Dword1
Dword2
Page 8 of 10