ESI ESRTP4+ Instruções para o utilizador - Página 7

Procurar online ou descarregar pdf Instruções para o utilizador para Termostato ESI ESRTP4+. ESI ESRTP4+ 11 páginas. Programmable room thermostat
Também para ESI ESRTP4+: Manual de instruções de instalação (11 páginas)

ESI ESRTP4+ Instruções para o utilizador

3. Operation Modes

Factory Pre-Set Programme

3.1
This Programmable Room Thermostat has been designed
to be a simple to use thermostat, requiring minimal user
intervention with a pre-programmed heating profile. The pre-
set heating times and temperatures will suit most people (see
table below). To accept the factory pre-set programme, move
the slider to AUTO which will revert the thermostat to Run
Mode (the colon (:) in the LCD display will begin to flash).
Pre-Set Temperatures: 5/2 Day
Key
Event
Time
1
06:00
2
08:00
3
12:00
4
14:00
5
17:00
6
22:00
N.B. If 4 events is chosen the events 3 & 4 are skipped
12
Temp
Event
Time
Temp
20°C
1
07:30
20°C
15°C
2
09:30
20°C
15°C
3
11:30
20°C
15°C
4
13:30
20°C
21°C
5
16:30
21°C
15°C
6
22:30
15°C
Pre-Set Temperatures: 7 Day
In 7 day setting, the pre-set settings are the same as the 5/2
Day programme.
Pre-Set Temperatures: 24 Hours
In 24hr setting, the pre-set settings are the same as Mon-Fri
of the 5/2 Day programme.
Setting the Operation Mode (5/2 day, 7 day, 24hr)
3.2
1. Switch the slider to PROG.
2. Press +/– buttons to move between 7 day, 5/2 day or
24hr operation.
5/2 Day operation is shown by MO, TU, WE, TH, FR
flashing (5 Day) and then SA, SU flashing (2 Day)
7 Day operation is shown by just one day flashing at
a time
24 hr operation is shown by MO, TU, WE, TH, FR, SA, SU
flashing at the same time.
3. Wait 15 seconds to automatically confirm and return
to Run mode or press Next
Programme'.
Setting the Program
3.3
1. Choose between 5/2 day, 7 day or 24 hr operation (see
above steps 1-2).
2. Press the Next
button. The time will flash and P1 will
be displayed (the 1st temperature event).
3. Press +/– to set the time (10 minutes increments). Press
the Next
button and the temperature will flash.
4. Press +/– to set the temperature (increments of 0.5°c).
Press the Next
button to go to the next time
temperature event (e.g. P2).
to move to 'Setting the
13