dixell CX620 Instruções de instalação e de utilização - Página 5

Procurar online ou descarregar pdf Instruções de instalação e de utilização para Controlador dixell CX620. dixell CX620 5 páginas.
Também para dixell CX620: Instruções de instalação e de utilização (5 páginas)

dixell CX620 Instruções de instalação e de utilização
dIXEL
Label Name
OE Evaporator probe calibration
P3P Third probe presence (1st cond.
probe)
O3
Third probe calibration
P4P Fourth probe presence (2nd
cond.
probe)
O4
Fourth probe calibration
OdS Outputs activation delay at start up
AC Anti-short cycle delay
Ac1 Second compressor delay
rtr
P1-P2 percentage for regulation
CCt Compressor ON time during fast
freezing
CCS Set point for continuous cycle
COn Compressor ON time with faulty probe
COF Compressor OFF time with faulty
probe
DISPLAY
CF
Temperature measurement unit
rES Resolution (integer/decimal point)
rEd Remote display
dLy Display temperature delay
dtr
P1-P2 percentage for disply
DEFROST
tdF Defrost type
dFP Probe selection for defrost termination
dtE Defrost termination temperature
IdF Interval between defrost cycles
MdF (Maximum) length for 1° defrost
dSd Start defrost delay
dFd Displaying during defrost
dAd MAX display delay after defrost
Fdt Draining time
dPO First defrost after start up
dAF Defrost delay after fast freezing
AUXILIARY THERMOSTAT
ACH Kind of action for auxiliary relay
SAA Set Point for auxiliary relay
SHy Differential for auxiliary relay
ArP Probe selection for auxiliary relay
Sdd Aux.output working during defrost
ALARMS
ALP Probe setting for temperature alarm
ALC Temperature alarms configuration
ALU MAXIMUM temperature alarm
ALL minimum temperature alarm
AFH Temperature alarm and fan differential
ALd Temperature alarm delay
dAO Delay of temperature alarm at start up
AP2 Probe for temperat. alarm of
condenser
AL2 Condenser for low temperat. alarm
AU2 Condenser for high temperat. alarm
Differ. for condenser temp. alar.
AH2
recovery
Ad2 Condenser temperature alarm delay
Delay of cond. temper. alarm at start
dA2
up
Compr.
off
for
condenser
bLL
temperature alarm
Compr.
off
for condenser high
AC2
temperature alarm
AUXILIARY OUTPUT
tbA Alarm relay disabling
oA3 Fourth relay configuration
AoP Alarm relay polarity (oA3=ALr)
DIGITAL INPUT
i1P Digital input polarity
i1F Digital input configuration
did Digital input alarm delay
Nps Number of activation of pressure
switch
odc Compress and fan status when open
door
rrd
Regulation restart with door open
alarm
HES Differential for Energy Saving
OTHER
PbC Kind of probe
Adr Serrial address
onF on/off key enabling
dP1 Room probe display
dP2 Evaporator probe display
dP3 Third probe display
1592026010 XW40K GB R1.0 22.02.2008.doc
Installing and Operating Instructions
Range
-12÷12°C /-120÷120°F
n=not present; Y=pres.
-12÷12°C /-120÷120°F
n=not present; Y=pres.
-12÷12°C /-120÷120°F
0÷255 min.
0÷30 min.
0÷255s
0 ÷ 100 (100=P1 , 0=P2)
0 ÷ 23h 50 min.
(-55.0÷150,0°C)
0÷255 min.
0÷255 min.
°C ÷ °F
in ÷ de
P1 ÷ 1r2
0 ÷ 20.0 min (10 sec.)
1 ÷ 99
EL, in
nP; P1; P2; P3; P4
-50,0÷110°C / -58÷230°F
1÷120h
0÷255 min.
0÷99min
rt, it, SEt, dEF, dEG
0÷255 min.
0÷60 min.
n ÷ y
0 ÷ 23h 50 min.
CL; Ht
-50,0÷110°C / -58÷230°F
0,1÷25,5 °C / 1÷45°F
nP / P1 / P2 / P3
n, y
P1÷P4
rE÷Ab
-50,0÷110°C / -58÷230°F
-50,0÷110°C / -58÷230°F
0,1÷25,5 °C / 1÷45°F
0÷255 min.
0 ÷ 23h 50 min.
nP; P1; P2; P3; P4
(-55 ÷ 150°C) (-67÷ 302°F)
(-55 ÷ 150°C) (-67÷ 302°F)
[0,1°C ÷ 25,5°C] [1°F ÷ 45°F]
0 ÷ 254 (min.) , 255=nU
0.0 ÷ 23h 50'
low
n(0) - Y(1)
n(0) - Y(1)
n=no; y=yes
ALr = alarm; dEF = do not select it;
Lig =Light; AUS =AUX; onF=always
on; Fan= do not select it; db = do
not select it; dF2 = do not select it
oP; cL
oP=opening;CL=closing
EAL, bAL, PAL, dor; dEF; Htr, AUS
0÷255min
0 ÷15
no; Fan; CPr; F_C
n – Y
-30°C÷30°C; -54°F÷54°F
Ptc; ntc
1÷247
nu, oFF; ES
--
--
--
Default Level
Label Name
dP4 Fourth probe display
0.0
Pr2
rSE Current set point
n
Pr2
rEL Software release
0
Pr2
Ptb Map code
n
Pr2
0
Pr2
0
Pr2
1
Pr1
5
Pr2
100
Pr2
0.0
Pr2
-5
Pr2
15
Pr2
30
Pr2
°C
Pr2
dE
Pr1
P1
Pr2
0
Pr2
50
Pr2
EL
Pr1
P2
Pr2
8.0
Pr1
6
Pr1
30
Pr1
0
Pr2
it
Pr2
30
Pr2
0
Pr2
n
Pr2
0.0
Pr2
cL
Pr2
0,0
Pr2
2,0
Pr2
nP
Pr2
n
Pr2
P1
Pr2
rE
Pr2
10,0
Pr1
10,0
Pr1
2,0
Pr2
15
Pr2
1,3
Pr2
P4
Pr2
-40
Pr2
110
Pr2
5
Pr2
15
Pr2
1,3
Pr2
n
Pr2
n
Pr2
y
Pr2
Lig
Pr2
cL
Pr2
cL
Pr1
dor
Pr1
15
Pr1
15
Pr2
F-c
Pr2
y
Pr2
0
Pr2
dIXEL
1
Pr2
Z.I. Via dell'Industria, 27 - 32010 Pieve d'Alpago (BL) ITALY
ntc
Pr1
tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 98 93 13
oFF
Pr2
http://www.dixell.com
-
Pr1
-
Pr1
-
Pr1
XW40K
S.p.a.
E-mail:
1592026010
Range
Default Level
--
-
Pr1
-
Pr1
- - -
1,1
Pr2
- - -
-
Pr2
5/5