dixell COOL MATE XLH360 Manual de Instruções - Página 11

Procurar online ou descarregar pdf Manual de Instruções para Controlador de temperatura dixell COOL MATE XLH360. dixell COOL MATE XLH360 16 páginas. Cool mate temperature and humidity controller for seasoning-maturing cabinets

dixell COOL MATE XLH360 Manual de Instruções
dIXEL
10.5 HEATING RELAY SAFETY (i1F=Ht)
With i1F=Ht as soon as the digital input is activated for "did" time heating relay is disabled.
The alarm will stop as soon as the digital input is de-activated.
10.6 DIGITAL INPUTS POLARITY
The digital input polarity depends on the "i1P" parameters. CL : the digital input is activated by closing the contact; OP : the digital input is activated
by opening the contact

11. INSTALLATION AND MOUNTING

The temperature range allowed for correct operation is 0 - 60 °C. Avoid places subject to strong vibrations, corrosive gases, excessive dirt or
humidity. The same recommendations apply to probes. Let the air circulate by the cooling holes.
Thanks to the case XLH360. See the following instructions for details.
F
D
A
C
FIG. 1
87
H
1592017410 XLH360 GB r1.0 15.04.2005.doc
Operating Instructions
F
G
E
D
B
230
130
FIG. 3
XLH360
cod. 1592017410
G
B
C
A
FIG. 2
I
11/16