dixell T620 Manual de instruções de instalação e funcionamento - Página 6

Procurar online ou descarregar pdf Manual de instruções de instalação e funcionamento para Controlador de temperatura dixell T620. dixell T620 6 páginas. Dixell temperature controller
Também para dixell T620: Instruções de instalação e funcionamento (5 páginas)

dixell T620 Manual de instruções de instalação e funcionamento
Label
Name
P2P Evaporator probe presence
oE Evaporator probe calibration
Third probe presence (1st cond.
P3P
probe)
o3 Third probe calibration
Fourth probe presence (2nd
P4P
cond. probe)
o4 Fourth probe calibration
Outputs activation delay at start
odS
up
AC Anti-short cycle delay
Ac1 Second compressor delay
rtr
P1-P2 percentage for regulation
Compressor ON time during fast
CCt
freezing
CCS Set point for continuous cycle
Compressor ON time with faulty
Con
probe
Compressor OFF time with faulty
CoF
probe
CF Temperature measurement unit
rES Resolution (integer/decimal point)
rEd Remote display
dLy Display temperature delay
dtr P1-P2 percentage for disply
tdF Defrost type
Probe selection for defrost
dFP
termination
dtE Defrost termination temperature
idF Interval between defrost cycles
MdF (Maximum) length for 1° defrost
dSd Start defrost delay
dFd Displaying during defrost
dAd MAX display delay after defrost
Fdt Draining time
dPo First defrost after start up
dAF Defrost delay after fast freezing
FnC Fans operating mode
Fnd Fans delay after defrost
Differential of temperature for
FCt
forced activation of fans
FSt Fans stop temperature
Fon Fan on time with compressor off
FoF Fan off time with compressor off
Probe selection for fan
FAP
management
AUXILIARY THERMOSTAT
ACH Kind of action for auxiliary relay
SAA Set Point for auxiliary relay
SHy Differential for auxiliary relay
ArP Probe selection for auxiliary relay
Sdd Aux.output working during defrost
Probe setting for temperature
ALP
alarm
ALC Temperature alarms configuration
ALU MAXIMUM temperature alarm
ALL minimum temperature alarm
Temperature alarm and fan
AFH
differential
ALd Temperature alarm delay
Delay of temperature alarm at
dAo
start up
Probe for temperat. alarm of
AP2
condenser
Condenser for low temperat.
AL2
alarm
Condenser for high temperat.
AU2
alarm
Differential for condenser
AH2
temperature alarm recovery
Condenser temperature alarm
Ad2
delay
Delay of cond. temper. alarm at
dA2
start up
Compressor off because of
bLL
condenser low temperature alarm
1592026020 XW60K GB R2.1 22.06.2012.doc
Range
Default Level
n=not present; Y=pres.
[-12 to 12°C]
[-21 to 21°F]
n=not present; Y=pres.
[-12 to 12°C]
[-21 to 21°F]
n=not present; Y=pres.
[-12 to 12°C]
[-21 to 21°F]
0 to 255 min
0 to 30 min
0 to 255 sec
0 to 100 (100=P1 , 0=P2)
0.0 to 23h50min, res. 10 min
[-55.0 to 150.0°C]
[-67 to 302°F]
0 to 255 min
0 to 255 min
DISPLAY
°C; °F
in; dE
P1; dtr
0.0 to 20min00sec, res. 10 sec
1; 100
DEFROST
EL; in
nP; P1; P2; P3; P4
[-50.0 to 150°C]
[-58 to 302°F]
1 to 120 h
0 to 255 min
0 to 99 min
rt; it; SEt; dEF; dEG
0 to 255 min
0 to 60 min
n; Y
0.0 to 23h50min, res. 10 min
FANS
C-n; C-y; O-n; O-y
0 to 255 min
[0 to 50°C]
[0 to 90°F]
[-55.0 to 50°C]
[-67 to 302°F]
0 to 15 min
0 to 15 min
nP; P1; P2; P3; P4
CL; Ht
[-55.0 to 150°C]
[-67 to 302°F]
[0.1 to 25.5°C]
[1 to 45°F]
nP; P1; P2; P3
n; Y
ALARMS
P1; P2; P3; P4
rE; Ab
[-55.0 to 150.0°C]
[-67 to 302°F]
[-55.0 to 150.0°C]
[-67 to 302°F]
[0.1 to 25.5°C]
[1 to 45°F]
0 to 255 min
0.0 to 23h50min, res. 10 min
nP; P1; P2; P3; P4
[-55.0 to 150.0°C]
[-67 to 302°F]
[-55.0 to 150.0°C]
[-67 to 302°F]
[0.1 to 25.5°C]
[1 to 45°F]
0 to 254 min , 255=nU
0.0 to 23h50min, res. 10 min
n(0); Y(1)
Label
Y
Pr1
Compr. off for condenser high
AC2
temperature alarm
0.0
Pr2
tbA Alarm relay disabling
n
Pr2
0
Pr2
oA3 Fourth relay configuration
n
Pr2
AoP Alarm relay polarity (oA3=ALr)
0
Pr2
i1P Digital input polarity
i1F Digital input configuration
0
Pr2
did Digital input alarm delay
1
Pr1
Number of activation of pressure
nPS
5
Pr2
switch
100
Pr2
Compress and fan status when
odC
open door
0.0
Pr2
Regulation restart with door open
rrd
alarm
-5
Pr2
Light off during energy saving
LES
status
15
Pr2
HES Differential for Energy Saving
30
Pr2
Hur* Current hour
°C
Pr2
Min* Current minute
dE
Pr1
dAY* Current day
P1
Pr2
dYM* Day of the month
0
Pr2
Mon Month
50
Pr2
YAr Year
Hd1* First weekly holiday
EL
Pr1
Hd2* Second weekly holiday
Energy Saving cycle start during
P2
Pr2
ILE*
workdays
Energy Saving cycle length during
8.0
Pr1
dLE*
workdays
6
Pr1
Energy Saving cycle start on
ISE*
30
Pr1
holidays
0
Pr2
Energy Saving cycle length on
dSE*
it
Pr2
holidays
30
Pr2
Ld1* 1
st
workdays defrost start
0
Pr2
Ld2* 2
nd
workdays defrost start
n
Pr2
rd
Ld3* 3
workdays defrost start
0.0
Pr2
Ld4* 4
th
workdays defrost start
Ld5* 5
th
workdays defrost start
o-n
Pr1
Ld6* 6
th
workdays defrost start
10
Pr1
Sd1* 1
st
holiday defrost start
Sd2* 2
nd
holiday defrost start
10
Pr2
Sd3* 3
rd
holiday defrost start
Sd4* 4
th
holiday defrost start
2
Pr1
th
Sd5* 5
holiday defrost start
0
Pr2
th
Sd6* 6
holiday defrost start
0
Pr2
Adr Serrial address
P2
Pr2
PbC Kind of probe
onF on/off key enabling
CL
Pr2
dP1 Room probe display
dP2 Evaporator probe display
0.0
Pr2
dP3 Third probe display
dP4 Fourth probe display
2.0
Pr2
rSE Current set point
nP
Pr2
rEL Software release
n
Pr2
Ptb Map code
* Only for model with real time clock
P1
Pr2
rE
Pr2
10.0
Pr1
10.0
Pr1
2.0
Pr2
15
Pr2
1.3
Pr2
P4
Pr2
-40
Pr2
110
Pr2
5
Pr2
15
Pr2
1.3
Pr2
n
Pr2
XW60K
Name
Range
n(0); Y(1)
AUXILIARY OUTPUT
n=no; Y=yes
ALr = alarm; dEF = do not select it; Lig
=Light; AUS =AUX; onF=always on; Fan=
do not select it; db = do not select it; dF2 =
do not select it
oP; CL
DIGITAL INPUT
oP=opening;CL=closing
EAL; bAL; PAL; dor; dEF; Htr; AUS
0 to 255 min
0 to 15
no; FAn; CPr; F_C
n; Y
n; Y
[-30 to 30°C]
[-54 to 54°F]
RTC
read only
read only
read only
read only
read only
read only
Sun to SAt; nu
Sun to SAt; nu
0.0 to 23h50min
0.0 to 24h00min
0.0 to 23h50min
0.0 to 24h00min
0.0 to 23h50min; nu
0.0 to 23h50min; nu
0.0 to 23h50min; nu
0.0 to 23h50min; nu
0.0 to 23h50min; nu
0.0 to 23h50min; nu
0.0 to 23h50min; nu
0.0 to 23h50min; nu
0.0 to 23h50min; nu
0.0 to 23h50min; nu
0.0 to 23h50min; nu
0.0 to 23h50min; nu
OTHER
1 to 247
PtC; ntC
nu, oFF; ES
read only
read only
read only
read only
read only
read only
read only
Default Level
n
Pr2
Y
Pr2
Lig
Pr2
CL
Pr2
CL
Pr1
dor
Pr1
15
Pr1
15
Pr2
F-C
Pr2
Y
Pr2
Y
Pr2
0
Pr2
-
rtc
-
rtc
-
rtc
-
rtc
-
rtc
-
rtc
nu
rtc
nu
rtc
0
rtc
0
rtc
0
rtc
0
rtc
6.0
rtc
13.0
rtc
21.0
rtc
0.0
rtc
0.0
rtc
0.0
rtc
6.0
rtc
13.0
rtc
21.0
rtc
0.0
rtc
0.0
rtc
0.0
rtc
1
Pr1
ntC
Pr2
oFF
Pr2
-
Pr1
-
Pr1
-
Pr1
-
Pr1
Pr1
-
Pr2
-
Pr2
6/6