ClearOne CLOCKAUDIO TS-001 Nota técnica - Página 4

Procurar online ou descarregar pdf Nota técnica para Sistema de conferência ClearOne CLOCKAUDIO TS-001. ClearOne CLOCKAUDIO TS-001 6 páginas. Using the clockaudio ts-001 with the converge pro

4.
Click on the Inactive (High) Command button.
5.
In Command Editor, select the appropriate Unit Type and DID then choose command of MUTE, Channel 1 and Group M:
a.
If the touch pad switch is to act as a push to talk switch, choose Mode 1.
b.
If the touch pad switch is to act as a push to mute switch, choose Mode 0.
c.
Click the Apply button located in the lower-right.
6.
Select Control Port A and Select Pin 2.
7.
Click on the Active (Low) Command button.
8.
In Command Editor, choose command of
1's Mute state is ON, Pin 2 will be pulled low to ground and the relay will energize. The relay will switch the ground to the red wire, thus the red
LED's illuminate.
9.
Click on the Inactive (High) Command button.
10. In Command Editor, choose command of
1's Mute state is OFF, Pin 2 will go high or float and the relay will de-energize. The relay will switch the ground to the green wire, thus the green
LED's illuminate.
Repeat the above process for microphone Channel 2 using Control Port A Select Pins 3 and 4, microphone Channel 3 using Control Port A
Select Pins 5 and 6, and so on for all 8 microphone channels.
CONVERGE PRO 840T CONFIGURATION

EQUIPMENT LIST

Converge Pro 840T
Clock Audio TS-001
Relay (RDL ST-LCR)
External 12 Volt DC Power Supply
DB25 Male Connector
Wire (22 Gauge Recommended)
WIRING
The ClockAudio TS-001 wiring requirements are shown in Image 3.
MUTE
, Channel 1 and Group M, and Mode 1 from the pull-down lists. When microphone Channel
MUTE
, Channel 1 and Group M, and Mode 0 from the pull-down lists. When microphone Channel
Image 3