Altox TRACKER-4 Manual de operação - Página 4
Procurar online ou descarregar pdf Manual de operação para Acessórios para automóveis Altox TRACKER-4. Altox TRACKER-4 4 páginas.
Settings
You can enter several settings simultaneously, dividing them by commas.
If the password is set (PASS:XXXX), then before entering any instruction,
you should include its value with no spaces (XXXXSETTINGS1).
Messages are not case sensitive.
When sending instructions from server using TCP, add «cmd_» before
command (for example, cmd_SMSF1).
General Settings Instructions
Request SMS with device ID and settings 1
Request SMS with device ID and settings 2
Restore to factory default settings
1. To change the signal reporting time at input IN send PULSEIN:XX,
where XX is value in ms.
This setting prevents false triggers when sensors with a long period of
contact chatter are connected.
2. For pulse signals send SMS-command «PULSEOUT:XX» to the device's
SIM card number, where XX is the duration of the signal in seconds from 1
to 9999 value.
This instruction switches auxiliary output OUT1 into the pulse mode.
To switch OUT1 back into normal operation mode use the same command
with value 0 (PULSEOUT:0).
3. Setting KEEPOUT1 activates the option to save and to subsequently
restore of auxiliary output OUT1 state when the device's power supply is
switched off and then switched on, respectively.
To switch off this option send SMS-command KEEPOUT0 to the device.
4. By default, the device uses the option of forwarding all incoming
SMS text messages (SMSF1 setting) that are not commands to the phone
number used to send the last correct command or the the phone number
set up for the device NUM1, NUM2 or NUM3.
The text of the forwarded text message includes sender's phone number in
the first line and the text of the message.
To switch off this option send SMS-command SMSF0 to the device.
5. In the waiting mode the device controls the car system voltage.
When the heater is turned off and the voltage drops below the predefined
value XX (see settings, instruction SMSV:XX, where XX - threshold voltage),
the system will send an alarm SMS text message to the first authorized
phone number entered into settings (see settings, commands NUM1, NUM2,
NUM3).
The next alarm SMS text messages about the voltage drop will be sent
every 3 hours.
6. CALL0 setting switches the module into the mode of dropping
incoming calls which allows saving money (in this case output OUT1
reverses its state)..
7. To set up a password for each text message command send
PASS:XXXX to the device where XXXX is a 4-characters-long password.
8. Using SMS-commands NUM1, NUM2 and NUM3 save in the device
authorized phone numbers. Phone numbers should be entered in the
international format.
Command
Attention! Authorized phone numbers should not have caller identity
ID1 / SETTINGS1
restriction (the number should not be hidden), otherwise the device will
ID2 / SETTINGS2
drop the call.
SETDEFAULT
9. Use BAL:XXX, where XXX is the request account balance number, to
save the phone number to request account balance status via USSD.
10.Setting BTIMER1:N (where N is a number of days) sets the period of
time for automated account balance requests using USSD (BAL setting) and
sending the response to the first authorized phone number NUM1 / NUM2 /
NUM3.
This option allows automated control of the account balance SIM card of
the device.
To switch off this option send a text message command with value 0
(BTIMER1:0)
11. Setting BTIMER2:N (where N is a number of hours) is similar to
setting BTIMER1, with one exception: the response with the account
balance information is sent to the server equipment (TCP connection).
Attention! When USSD is used to request account balance information GPRS
session might be closed which can result in rounding off of Internet traffic.
Pulse time of the input signal IN, 1-9999ms
Pulse mode for OUT, 0-OFF (0-9999 sec)
Restoring of the state for OUT after power supply
Forwarding of incoming SMS (to switch off use SMSF0)
SMS about car system voltage drop
CALL1 - response incoming call, CALL0 - dropping call
Setting the password before entering SMS-commands
Save the phone number into cell NUM1
Save the phone number into cell NUM2
Save the phone number into cell NUM3
Save USSD number fore account balance requests
Timer for sending SMS with balance, 0-99 days (0-OFF) BTIMER1:10
Timer for sending balance into application, 1-9 hours
Transliteration of cyrillic characters
Technical Settings
Command
PULSEIN:500
PULSEOUT:0
KEEPOUT1 /0
SMSF1 /0
SMSV:11.0
CALL1 /0
PASS:XXXX
NUM1:+YYYYYYY
NUM2:+YYYYYYY
NUM3:+YYYYYYY
BAL:*XXX#
BTIMER2:5
TRANSLIT1 /0