Section G - Install End Verticals
Vertical members at both ends of your shelter are used to help support the ridge purlin.
Step 1: Connect an 84" unswaged pipe to the bottom of the 2 socket cross coupling that was pre-
installed at the middle of the chord. If you used ground posts, the bottom of this pipe should be
secured to the ground post in the same manner as the legs.
Step 2: Connect a 72" unswaged pipe between the top of the 2 socket cross of the chord to a
socket T & cross coupling at the end of the ridge purlin.
Step 3: Check for any sharp edges on the frame and either file them smooth or wrap them with a
layer or two of duck tape so they will not cut the cover.