E.) Installing the Signal Cable
IT IS IMPERATIVE TO WRAP THE COIL THE CORRECT NUMBER OF TIMES.
PLEASE SEE CHART BELOW FOR CORRECT NUMBER OF WRAPS.
UNIT TYPE
Pipe Type
AG-150
Copper Pipe
AG-150
Copper Pipe
AG-150
Copper Pipe
AG-150
Copper Pipe
AG-150
PVC/CPVC/PEX
AG-150
PVC/CPVC/PEX
AG-150
PVC/CPVC/PEX
AG-150
PVC/CPVC/PEX
AG-200
Copper Pipe
AG-200
PVC/CPVC/PEX
AG-200
Ferrous Pipe
AG-300
Copper Pipe
AG-300
Copper Pipe
AG-300
PVC/CPVC/PEX
AG-300
PVC/CPVC/PEX
AG-300
Ferrous Pipe
AG-400
Copper Pipe
AG-400
Copper Pipe
AG-400
PVC/CPVC/PEX
AG-400
PVC/CPVC/PEX
AG-400
Ferrous Pipe
JUST BECAUSE YOU HAVE EXTRA WIRE DOES NOT MEAN YOU HAVE TO USE IT! DO NOT OVER WRAP THE COILS
MORE THAN THE RECOMMENDED NUMBER. DO NOT UNDER WRAP THE AMOUNT OF COILS SUGGESTED. Over
wrapping can significantly decrease the power of the signal. If you are unable to obtain correct number of wraps due to straight
pipe issues of not giving you enough space, the minimum number of wraps the unit requires is at least 30 wraps.
MAKE SURE THE WRAPS ARE FLUSH AGAINST ONE ANOTHER – NEVER OVERLAPPING. THIS IS EXTREMELY
AS PREVIOUSLY NOTED, MAKE SURE THE CONTROL BOX IS MOUNTED AS CLOSE AS POSSIBLE TO WHERE THE SIGNAL
CABLE IS WRAPPED ON THE PIPE. THE MAXIMUM DISTANCE SHOULD NOT BE MORE THAN 10 FEET.
1.
Single Wrap
to power
box terminal
First layer
wrapping direction
3.
Double Wrap
Pipe Size
.75"
1"
1.25"
1.5"
.75"
1"
1.25"
1.5"
2"
2"
Call
2.5"
3"
2.5"
3"
Call
3.5"
4"
3.5"
4"
Call
Straight section of pipe away
from angles, tees, valves and couplings
Balance of ScaleBlaster
signal cable
Cable Tie
YOU MUST KEEP THE SECOND LAYER WRAPPING IN THE SAME DIRECTION AS THE FIRST!
Wrap right over the top of the first layer continuing in the same wrapping direction as the first layer – clockwise or
counterclockwise. This second and/or third layer must also be tight and touching the prior wrap.
Second layer wrapping direction
(same as the first)
Type of Coil
Wire Gauge
Double*
18
Double*
18
Double*
18
Double*
18
Double*
18
Single
18
Single
18
Single
18
Double*
12
Single
12
Call
12
Double*
12
Double*
12
Single
12
Single
12
Call
12
Double*
12
Double*
12
Single
12
Single
12
Call
12
IMPORTANT.
to power
box terminal
Page 7
(continued)
Wraps
50* wraps x 2
45* wraps x 2
40* wraps x 2
35* wraps x 2
70* wraps x 2
57
50
34
68* wraps x 2
82
Call
64* wraps x 2
60* wraps x 2
71
61
Call
58* wraps x 2
56* wraps x 2
52
40
Call
2.
See wrap
maximum
chart
Cable Tie
4.
continuing in the same direction
wrapping around the pipe as the first layer
*Example -
Double 80
wraps is a total
of 160 wraps.
80 wraps on
first layer and
80 on second
layer
Cable Tie