3i BSE-150 Manual de instalação - Página 7

Procurar online ou descarregar pdf Manual de instalação para Sistema de segurança 3i BSE-150. 3i BSE-150 8 páginas. Active indoor and outdoor infrared barrier with 3 beams of protection

7 - In case of problems

Problem
The indicator LEDs of transmit-
tor and receiver do not light
The
ALARM LED does not
light and the alarm trigger relay
does not change state if both
beams are interupted.
The ALARM LED lights when
both IR beams are interuped
but the contol panel does not
receive the trigger alarm signal.
ALARM trigger LED is alway
light.
False alarm signal
8 - Techical Characteristics
MAXIMUM RANGE . . . . . . . . . . . . . . . .
NUMBER OF BEAMS . . . . . . . . . . . . . .
OPERATING MODE . . . . . . . . . . . . . . . .
TECHNOLOGY IR TRANSMISSION . . .
RISPONSE TIME . . . . . . . . . . . . . . . . . .
ALARM OUTPUT . . . . . . . . . . . . . . . . .
POWER . . . . . . . . . . . . . . . . . . . . . . . . .
CURRENT DRAIN . . . . . . . . . . . . . . . . .
FUNCTIONING TEMPERATURE. . . . . .
HORIZONTAL ANGLE. . . . . . . . . . . . . .
VERTICAL ANGLE . . . . . . . . . . . . . . . .
SENSOR MATERIAL. . . . . . . . . . . . . . .
WEIGHT. . . . . . . . . . . . . . . . . . . . . . . . .
Instruction Manual BSE-150
Cause
12 Vdc. not present or defective
power source present.
1- Check if the receiver is getting the
barrier signal from another near by
transmitter.
2- Check if both beams are interup-
ted at the same time.
3- Check if the trigger response time
is correctly set.
1- Check the terminal connections
and if there is an open or short
circuit.
2- Check for error on the terminal
connections.
1- The IR beams are not aligned.
2- There is something that prevents
the IR beam from arriving.
3- The sensor cover is very dirty.
1- Bad cable connections to the
control panel.
2- Bad 12 Vdc. Power source.
3- Obtacales present that will interup
the IR beams always or only when
there is wind
4- Instable coloum
5- The signal received is not strong
enough. Below 2.3 V.
6- The trigger response time is not
correct.
Indoor 300 mt. Outdoor 100 mT.
3
Interuption of both beams together
Active Infrared
From 50 to 700 Msec
30 V. 0,5 mA max. (a.c. or d.c.)
From 10,5 to 18 Vd.c.
80 mA max.
Da –25°C to +55°C (from 5% to 95% humidity)
180° (-90°+ 90°)
20° (-10°+ 10°)
ABS
Trasmitter 630 g - Riceiver 660 g
ENGLISH
Solution
Check the connection cables for
short circuit or bad connection.
1- Remove the transmitter that is
causing the interference.
2- Make sure that both beams are
interupted
3- Regulate the trigger reponse
time so that the unit will function
correctly.
1- Check for damaged cables
2- Check that the terminal
connection are correct.
1- Re-align the IR beams and test.
2- Remove any obstacales that
can prevent the IR beams to arrive
3- Clean the sensor cover.
1- Check that the cables make
good connection.
2- Check that the input power is
okay.
3- Remove all obstacales or
change the IR beam path.
4- Change or fix better the support
5- Re-align the the IR beams
6- Change the trigger response
time so that the unit works
correctly.
Pag. 7