WiringSystem:
Terminals 2 and 3: Connect
to Temperature sensor
(included).
Ground Terminal: Use #12
AWG Wire. (Recommend
to Battery Negative Post or
Good Chassis Ground
Point)
Connect this wire
first!
IGN Ctrl
– Connect ignition signal or other switched signal to IGN Ctrl terminal. This input will allow
when ignition is turned on/off. Also, ignition can control system power up and down if
Configure section)
Trig1 Trig 2
– This input will allow
SETUP
menus (see Configure section)
(Trig
enabled) channels to turn on/off when Trig 1 or Trig2 signal is turned on/off. Feature must be enabled in
1411 S. Roselle Rd. Schaumburg, IL 60193
www.AltronicsInc.com
Connect Cable from Touch Screen
(Trig enabled
Ignition/Switch Power
Phone (847) 923-0002 Fax (847) 923-0004
Battery +
: Use minimum
4 AWG cable. Connect to
Positive Post on Battery
IMPORTANT: Install
independent cable direct
to battery or battery
disconnect switch
Do not splice from another
power cable or junction.
Max torque on nuts:
24 inch-lb
(2 ft-lb)!!!
For Circuits (Starter, Ignition, Fuel,
etc..) use appropriate 14awg (30
amp), 16awg (20 amp), or 18awg (15
amp) wire depending on load.
(IGN)) channels to turn on/off
off is enabled in
SETUP
menus (see
(kill switch).