AIMS Power CON120AC24VDC Manual do utilizador - Página 10
Procurar online ou descarregar pdf Manual do utilizador para Carregador de bateria AIMS Power CON120AC24VDC. AIMS Power CON120AC24VDC 11 páginas. Ac converter / battery charger
AC power present at
distribution panel
Green, yellow and red
LED blinking 0.5s
together
Red LED blinking 0.5s
other LEDs off
Red LED Blinking 2s
If any other situations occur that are not listed above, call AIMS Power immediately.
4
.
S
p
e
c
i
f
i
c
a
t
i
o
n
4
.
S
p
e
c
i
f
i
c
a
t
i
o
4
.
1
I
n
p
u
t
4
.
1
I
n
p
u
t
Input Voltage
Frequency
Nominal Input Current at Rated
Output
Voltage Measurement Accuracy
Frequency Measurement Accuracy ±1Hz
4
.
2
O
u
t
p
u
t
4
.
2
O
u
t
p
u
t
Nominal Voltage
Output Current
Rated Output Current
Current Accuracy
Load Regulation
Current Limit
Dead-Battery Charging
Selectable Battery Type
Parallel Outputs
Efficiency
Power switch is not on
AC input is missing
Breaker has popped
Mode select fault
Fan fault
The charger is operating
over temperature
s
n
s
96-145VAC full performance
70-96VAC automatically de-rate to 50% of full load current
40Hz to 70Hz
<9Aac
±8Vac
12/24Vdc auto adjusting
Input voltage 96-145V,
output current 75A for 12V mode
output current 37.5A for 24V mode
Input voltage 70-96V,
output current 37.5A for 12V mode
output current 18.75A for 24V mode
Auto adjust to 12/24V
± 6% of full rated output current @25°C, for target currents
across the range from 10% rated output (for absorption exit
criteria accuracy) to the current limit setpoint.
1.5%
75-80Amp
8-14.9Vdc at 100% of rated output current
8-29.8Vdc at 100% of rated output current
Open Lead-Acid, Gel, AGM, LiFePo4, adjustable
Maximum of two AC converter units connected in parallel
80%
Press and hold power switch.
Check AC input connections.
Reset the input protector.
12V mode: Adjust battery voltage lower than
15V
24V mode: Adjust battery voltage higher
than 18V
Check the fan in charger. Thermal/load based
On the heat sink of DC-DC part should be
operate below 105°C
- 10 -