3.
Characteristics
The characteristics of the occupancy sensor can be summarized as follows;
Extended range of detection.
Coated aluminum housing and adjustable stainless steel mounting bracket.
Provided with two Ex e cable glands.
Manufactured on the basis of the European Directive 2014/34/EU (ATEX 114).
Suitable for use in gas and dust hazardous areas classified as zone 2 and 22.
Explosion safety category and protection degree against ignition applied:
II 3 G Ex ec mc IIC T6 Gc
II 3 D Ex mc tc IIIC T80˚C Dc.
Protection degree against the ingress of water and dust IP 65.
Suitable for indoor use.
4.
CE - Marking
The occupancy sensor complies to the European Directives for EMC and ATEX and implicit to the Low Voltage
Directive. With regard to explosion safety the occupancy sensor has been designed and manufactured on the basis of
the essential health and safety requirements of European Directive 2014/34/EU (ATEX 114) relating to Group II
Category 3GD. Harmonized European construction standards have been applied fulfilling the essential requirements of
the directives.
5.
Application
The explosion-safe AR-024 occupancy sensor has been designed for and is suitable for use in hazardous classified
areas due to flammable gases, vapors, mist, fibers and dust. Because it is explosion-safe and certified on the basis of
Group II Category 3GD of the ATEX Directive it is suitable for use in the following types of zones in explosion
hazardous areas:
for combustible gases, vapors and mist: zone 2
for combustible fibers and dust: zone 22.
6.
Technical data
Explosion safety category:
Protection against ignition:
Conformity:
Standards applied:
Sensor:
Mounting height:
Range of coverage:
Registration angle:
Dimmer setting:
Preset time:
Supply voltage:
User manual explosion-safe AR-024 occupancy sensor
Issue April 2020
ATEX II 3GD
Ex ec mc IIC T6 Gc, Ex mc tc IIIC T80˚C Dc
European Directive 2014/34/EU (ATEX 114) and 2014/30/EU (EMC)
EN 60079-0:2018, EN 60079-7:2015 / A1:2018, EN 60079-18:2015 / A1:2017 and
EN 60079-31:2014
Passive infrared; 0,8 W power consumption
2 – 10 m
An oval area of 24 x 44 m
Circular 360°
10 – 2,000 Lux
15 seconds – 30 minutes
230 VAC ± 10%
4 / 8