The RE629 Glassbreak
the sound of breaking glass and sends alarm signals to
the security panel.
Features
• Variable detection range of up to 20 feet
• Low battery and tamper indication
• VHB™ tape included for easy installation
Enroll
by placing the panel into wireless enrollment mode
and sending an enrollment signal. Alternatively, the
sensor can be enrolled by scanning its bar code using
the Connect+ Installer App or by entering its 8-character
serial number in the AlulaConnect portal.
Sending an Enrollment Signal
• Remove the battery tab to power the device or
tamper the device by opening the enclosure.
Select sensitivity by adjusting the dipswitch. See table
below for sensitivity settings.
SENSITIVITY
MAX
MEDIUM
LOW
LOWEST
Select a mounting location
6.5 feet (2m) and no more than 20 feet (6m) from the
window you wish to protect. Ensure the sensor has
visual line-of-sight to all windows being protected.
Use a glassbreak tester to confirm operation before
permanently mounting using the mounting screws or
VHB tape.
Test the glassbreak
and installation. Note, any glassbreak tester can be
used.
1. The sensor is in test mode for 5 minutes after
powered. When test mode is active, the LED will
flash once per second.
2. Activate the glassbreak tester near the window you
wish to protect.
3. If an alarm is detected, the LED will flash rapidly
for 2 seconds and an alarm signal will be sent to
the panel. If the sensor does not trip, check the
sensitivity setting or relocate the sensor and retest.
Use the panel installation guide to verify proper system setup.