may present a risk of fire or explosion.
7.4 Cleaning your Alarm
Clean your Alarm regularly. Use a soft
bristle brush or the brush attachment of
your vacuum cleaner to remove dust and
cobwebs from the side slots where the
smoke enters. To clean the cover, wipe
with a damp cloth and dry thoroughly.
WARNING: Do not paint your Alarm.
Other than the maintenance and cleaning
described in this leaflet, no other
customer servicing of this product is
required. Repairs, when needed, must be
performed by the manufacturer.
7.5 Chamber Cleaning
Cleaning or replacing of the chamber
cover should only be carried out by
suitably trained personal.
1. Remove the Alarm from the mounting
plate.
2. Remove the batteries.
3. With a flat screwdriver unclip the three
cover clip points (see figure 8a).
4. Remove the cover (see figure 8b).
5. Unplug the thermistor by holding the
thermistor PCB and pulling the pins out
of the sockets (see figure 8c).
6. To remove the chamber top turn the
chamber anti-clockwise approx. 15
degrees (see figure 8d).
7. Blow out or use a soft bristled brush to
remove dust and dirt form the chamber
base.
8. Fit a new chamber top and clip in place
by turning clock-wise 15 degrees.
9. Insert the thermistor PCB into the
sockets and ensure the thermistor is
perpendicular to the chamber (see
figure 8e).
10. Place the cover back on the Alarm
taking care to ensure the thermistor
is protruding out the cover (see figure
8f).
11. Replace the batteries and reattach to
the mounting plate.
12. Press the test button to ensure the
Alarm is working correctly.
Figure 8a
Figure 8b
Figure 8c
Figure 8d
Figure 8e
10