Cutler-Hammer 8280A Manual de instruções - Página 2

Procurar online ou descarregar pdf Manual de instruções para Unidade de controlo Cutler-Hammer 8280A. Cutler-Hammer 8280A 2 páginas. 80 series photoelectric time delay logic card

Page 2
CONTROLS AND ADJUSTMENTS
The timing range is switch selected according to the selection
chart printed on the label. Paste the label on the inside of the
control module's side cover for future reference. The length of
time delay may be varied, within the range selected, by
adjusting the pulse width potentiometer (clockwise = increase).
The selected timing range applies to both LT and DRK delay.
8280A
TIME DELAY
RANGE
(SEC)
.01 - .20
.10 - 2.0
1.0 - 20
TIMING DIAGRAM:
Condition 1 - DRK delay prevents the output from changing at
the same moment the beam is blocked (DRK).
Condition 2 - LT delay prevents the output from changing at
the same moment the beam is completed (LT).
Still Need Help?
Contact the
Cutler-Hammer Sensor
Application Engineers
1-800-426-9184
Fax: 425-513-5356
INCR
LT
DRK
DELAY
DELAY
SWITCH
1
2
3
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
Cutler-Hammer
720 80th Street SW
Everett, WA 98203-6299
425/513-5300 Fax: 425/513-5302
www.cutlerhammer.eaton.com
Effective 5/20/97
Printed in U.S.A.
Slide the numbered switch upward for the "ON" position. In the
example below, 1 and 2 are set to "ON," and 3 is "OFF."
With the installation of a logic card, the control module's
output is governed by the settings of the logic card rather
than the status of the infrared light beam. For the following
timing diagrams, assume that the control module is set for LT
mode operation (beam complete = output on); DRK mode
operation is similar.
Condition 3 - LT and DRK delay can be used together to offset
the output action.
Condition 4 - An event which is shorter than the set delay
period will be ignored and the delay reset.
104232 Rev 02