DLG PHOTOMETER 2 Manual de instruções - Página 10

Procurar online ou descarregar pdf Manual de instruções para Instrumentos de medição DLG PHOTOMETER 2. DLG PHOTOMETER 2 15 páginas. Focal plane metering system for large format photography

TECHNICAL AND PERFORMANCE DATA

The information contained in this section is for guidance only and represents typical,
rather than the guaranteed minimum performance. It is provided for the guidance of
specialist users with unusual applications and may be disregarded by the majority of
users.
Calibration
The meter has been calibrated to give a negative tone in the centre of the useable
range. Film tests have been carried out to determine the optimum point. See figure.
Note that the film base is not perfectly transparent and typically transmits around 50% of
the light. The test data has been adjusted accordingly, to give 0% for the lightest
possible (around 50% transmission) negative and 100% for a completely opaque
negative.
-3
-2
-1
0
0
Photometer 2 Instruction Manual
Measured HP5+ Characteristic
Calibration Point
1
2
Log Relative Exposure
10
DLGelectronics.com
Film Base
3
4
5