7.13 Hot-start Prevention
If power is interrupted to the DLM-4, the unit will restart the lights after
a 15 minute time delay to allow the lamps to cool before re-starting.
Each successive zone re-start will be preceded by a 5 second delay in
order to reduce electrical startup surges / loads. During the 15-minute
delay, the DLM-4 will show the time remaining until the lights will be
re-started, (turned On).
*NOTE:
In order to minimize start-up load or high power "spikes", after
a power outage each one of the 4-zones will be re-started sequentially.
After the first zone re-starts, a 5-second "cascading timer" delay will
begin for each of the remaining 3-zones to turn back on 1 at a time.
Zone 1
1000W70.7F
1000W
1000W
Day
Zone 2
---.--F
Restrike
14.31
Zone 3
---.-F
Restrike
14:31
Zone 4
---.-F
Restrike
14:31
01/19/17
*NOTE:
While the time delay is counting down, the Zone status menu
will display the time remaining, before the lights are allowed to re-
strike.
28
DLM-4 ZONE
Controller
7.14 Dimming and
High-temperature Shut Down
The DLM-4 Zone Controller has the ability to monitor the temperature
of 4-separate zones. The user can select their desired dimming and
high-temp shut down (Stop At) settings within the zone settings.
Dim at setting:
rises too high, the lights connected (assigned) to that zone will be
dimmed to reduce the temperature inside the growing area.
Stop at setting:
At" temperature setting is reached, the lights within that zone will be
turned off.
*NOTE:
the temperature is reduces by 2'C / 3.6'F below the dimming and the
Stop At setting. (The dimming or high-temp shutdown event will be
stored in memory within the error log menu.
Dimming start
04:41:25pm
03/08/2017
Temp: 70.8F
ENTER to Return
*NOTE:
If the temperature of any of the zones being monitored
If the temperature continues to rise, and the "Stop
The zones will return to normal operation automatically once
Zone 1
To return to the Zone status menu, press the Enter button.
DLM-4 ZONE
Controller
29