This appliance is designed for use with LPG ONLY. When this
appliance is to be permanently installed the installation should
only be carried out by a qualified gas fitter who is registered with
LPGSASA and that such installations should comply with the
requirements of SANS 10087-1 or SANS 827 as applicable.
Good room ventilation is vital for the efficient performance
of the appliance and for the safety of the occupants in the
room in which the appliance is installed.
Cooking appliances generate considerable heat. The layout
and materials of the surrounding cabinets should take
account of these characteristics.
Surfaces of cabinets immediately adjacent to the hob should
be able to withstand temperature of up to 100°C without
delaminating or discolouring.
Make sure that the unit is well levelled in relation to the
ground. Improper levelling can affect the function of the
appliance.
Ensure no items which can catch alight easily (eg. curtains)
are near the gas hob.
Allow an unrestricted air space of at least 150mm at the
sides and 750mm above the hob.
Diagrams below show the aperture dimensions in the work top to
install the gas hob
4 BURNER HOB
Before placing the hob in the counter cut out, the supplied foam
sealing strip must be attached to the underneath of the lip of the
hob. This prevents dirt and moisture from the counter top seeping
under the hob.

INSTALLATION

5 BURNER HOB
5
Note: This appliance is
designed for use with
a 2.8 kPa SANS 1237
regulator with SANS
1156-2 approved hose.
Using any other type
of regulator or hose is
extremely dangerous.
Regulator and hose
sold separately.