Et system Umpetha Manual do utilizador - Página 5

Procurar online ou descarregar pdf Manual do utilizador para Abertura de porta de garagem Et system Umpetha. Et system Umpetha 9 páginas. Sliding gate motor

Action
1.
Gate in closed position
2.
Press and release any PED
(pedestrian) input.
Any further PED (pedestrian) input triggers w hile the gate is running are ignored except in the pedestrian
opening position, w here the auto-close timer w ill simply reset.
Any BM (beam) input w hile the pedestrian routine is running w ill cause the gate to continue to the p edestrian
opening position or rev erse back to the pedestrian opening position. If already in the pedestrian op ening
position, the auto-close timer w ill simply reset.
Any BT (full opening input w hile the pedestrian routine is running w ill open the gate to the full op en position
and the unit w ill rev ert to the operating mode selection that has been setup.
If a collision, obstruction or hindrance is encountered before the full open position is reached while opening, the gate will
stop, back off and wait for the next trigger input before closing slowly. The status LED will flash rapidly while stationery after
backing off of collision. Closing trigger clears LED indication.
If a collision, obstruction or hindrance is encountered while closing, the gate will stop and reverse to the fully open position.
The next trigger input start the gate closing slowly. The status LED will flash rapidly while stationery after backing off of
collision. Closing trigger clears LED indication.
On encountering 4 consecutive obstructions while closing the gate, the UMPETHA will not reverse back to the full open
position. The response will be a 5 sec beep tone, followed by a gentle momentary reverse away from the obstruction. The
unit will now begin a mandatory 30sec lockout whereby the only response to any trigger input will result in a tone so long as
the trigger button is held. After 30sec a trigger input will result in a repeat of the 5 sec beep and the gate opening 1 meter
or to the full open position whichever is reached first. The unit will once again lock out. This time the user must manual release
the unit and test the travel by hand before attempting any further automation of the gate.
The Status LED will flash rapidly throughout this procedure indicating an obstruction has occurred.
Releasing the gearbox and re-engaging it will clear the LED status and the Collision lock out routine.
Collision with closed stopper due to faulty or missing closed limit. (All modes)
If no limit input is made when expected (as calculated by the programmed run time) the UMPETHA will not reverse back to
the open position as it normally would when obstructed. It will however stop at the point of impact with the closed catch
and emit a 5sec long beep tone. At the next valid opening trigger the UMPETHA will re-emit the 5sec long beep tone and
only open the gate by ±1 meter. This will allow for the user to be able to enter the property and manually override the gate.
The magnet actuator and limit can now be checked. If not corrected and further attempts are made to operate the
UMPETHA with a faulty closed limit condition the same routine will be repeated on every operation.
If the user continues to attempt to operate the gate without manually releasing the gearbox while the gate is at the ±1meter
position, the result will only be a repeat of the 5sec beep tone.
UMPETHA U 082009/072010.012
P edestrian opening
Available in all modes.
INHERENT SAFETY SENSING SYSTEM
Collision/obstruction/hindrance while opening. (All modes)
Collision/obstruction/hindrance while closing. (All modes)
Multiple collision/obstruction lock-outs. (All modes)
A) 3 x 1sec beeps after w hich gate opens
to pedestrian opening position.
B) At pedestrian opening position
pedestrian auto-close timer times out.
C) 3 x 1sec beeps after w hich gate re-
closes.
5
Response