3200ET Remote Meter
Control Operation (Cont'd.)
Operation During Programming
The control will only enter the Program Mode with the timer in Service and operating on line power. While in the
Program Mode the control will continue to operate normally monitoring water usage and keeping all displays up to date.
Control programming is stored in memory permanently with or without line or battery backup power.
Lockout Input Operation
The Lockout Arrow will turn on whenever a Lockout Signal is being received by the control. Any requests for
regeneration will be delayed until this signal is removed. Regeneration will then proceed normally.
Keypad Operation
Extra Cycle Button -
Pushing this button will initiate a regeneration cycle independently of actual timer conditions.
1. With immediate regeneration timers this extra regeneration would occur immediately.
2. With delayed regeneration timers this extra regeneration would occur at the set Regeneration Time. A regeneration
cycle can be forced to occur immediately by pushing and holding in for 5 seconds this button.
Totalizer/Flow Rate Button -
This button is used to view the Totalizer and Flow Rate Displays. Depressing the button once will display flow rate.
Depressing the button again will display the total accumulation of water flow through the meter since it was last reset.
Depressing the button once more will return the display to Time Of Day or Volume Remaining.
The Totalizer display is reset by depressing and holding this button for 25 seconds. During the 25 seconds, the Totalizer
Arrow will flash as an indicator to the operator that the display is being reset properly.
Program Button -
This button is used by the installer to program those settings indicated on the front panel by red LEDs.
Up Set Button -
This button is used to set the current time of day, adjust time remaining in a regeneration cycle step, and in timer
programming. The Up Arrow Button will increment a display setting.
Down Set Button -
This button is used to set the current time of day, adjust time remaining in a regeneration cycle step, and in timer
programming. The Down Arrow Button will decrement a display setting.
Low Battery Indicator
When the control is operating on line power this red LED will turn on whenever the 9V alkaline battery (Not Included)
used for memory backup needs to be replaced. The battery is stored against the timer backplate. In the event of a
power outage, the battery will maintain current operating displays for approximately 24 hours at maximum battery
capacity.