DOEPFER A-154 Manual - Página 7
Procurar online ou descarregar pdf Manual para Controlador DOEPFER A-154. DOEPFER A-154 16 páginas. Sequencer controller, system a-100
doepfer
2a Manual First (knob)
2b First CV (knob) / " First CV (socket)
3a Manual Last (Regler)
3b Last CV (knob) / § Last CV (socket)
This group of elements is responsible for the First and
Last step of the sequence. For both parameters a
manual control (knobs 2a and 3a) and an external
control voltage input (CV inputs " and §) are available.
The CV inputs are equipped with attenuators (knobs 2b
and 3b). The attenuators are used to adjust the level of
the corresponding external CV and consequently the
influence of the CV.
The required control voltage at the sockets " resp. § to
reach all steps is about 0...+5V (with attenuators 2b
resp. 3b at it's maximum and Manual First 2a resp.
Manual Last 3a at it's minimum position).
In the CV Controlled mode the first/last step function
does not work. Rather the controls and the CV input of
the First section (", 2a and 2b) are used in this mode
for the voltage addressed step position of the se-
quence. The controls and CV input of the Last section
have no function in this mode.
Note : If the sequencer seems not to work (i.e. it remains
at a fixed position) please check if the settings of first
and last step are the reason for this behaviour. If the
value of the last step is the same or smaller than the
value of the first step the sequence seems to stop ! But
System A - 100
actually always the same step is addressed due to the
settings of first and last step! If you do not want to use
the first/last step function the manual controls should be
set to minimum (2a Manual First) resp. maximum (3a
Manual Last) and no external CVs should be applied
resp. the attenuators (2b and 3b) should be set to
minimum.
4a Manual Clock (knob)
4b Clock CV (knob) / $ Clock CV (socket)
5a Manual PW (knob)
5b PW CV (knob) / % PW CV (socket)
This group of elements is responsible for the internal
clock generator. Both rate (clock) and gate length resp.
pulsewidth (PW) can be controlled independently. For
both parameters a manual control (knobs 4a and 5a)
and an external control voltage input (CV inputs $ and
%) are available. The CV inputs are equipped with
attenuators (knobs 4b and 5b). The attenuators are
used to adjust the level of the corresponding external CV
and consequently the influence of the CV.
The independent control of rate and pulsewidth leads to
a lot of interesting features. E.g. controlling PW by one
of the A-155 CV outputs allows a different gate length
for each step. But the tempo (resp. clock rate) is the
same for the whole sequence.
Sequencer Controller
A-154
7